Information Exceptions Mode Page

Table 40. Information Exceptions Mode Page

 

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

0

PS (0)

Reserved

 

 

Page Code (1Ch)

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

Page Length (0A)

 

 

 

 

 

 

 

 

 

 

 

 

2

Perf (0)

 

Reserved

 

DExcept

Test

Reserved

LogErr(0)

 

 

 

 

 

 

 

 

 

3

 

Reserved

 

 

MRIE (3)

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

:

 

 

 

Interval Timer (0)

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

:

 

 

 

Report Count (0)

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Information Exceptions mode page is used to control Exception Reporting by using the TapeAlert log page.

If the DExcept flag is clear, Exception Reporting is enabled. If the DExcept flag is set, Exception Reporting is disabled. The default for DExcept is 0.

If the Test flag is set, the next command will fail, the Sense Key will be set to Unit Attention, and the ASC/ASCQ will be set to Failure Prediction Threshold Exceeded - False (5DFF). If the Test flag is clear, the next command is processed normally. The default for Test is 0.

The Perf and LogErr flags must be 0. These features are not supported.

The MRIE field must be 3. If an exception occurs, the next command will get Check Condition status, the Sense Key will be set to Recovered Error, and the ASC/ASCQ will be set to Failure Prediction Threshold Exceeded (5D00).

The Interval Timer and Report Count must be set to 0. These fields are not supported.