IBM T200F manual Sequential Access Device Log Parameters, Parameter Description Length

Models: T200F T200

1 126
Download 126 pages 42.05 Kb
Page 36
Image 36

Sequential Access Device Log

The Sequential Access Device Log Page is 0Ch.

Table 21. Sequential Access Device Log Parameters

Parameter

Description

Length

DU

LP

LBIN

 

 

 

 

 

 

0h

Write Data Bytes

8

0

0

0

 

Received, before

 

 

 

 

 

compression

 

 

 

 

 

 

 

 

 

 

1h

Write Data Bytes

8

0

0

0

 

Received, after

 

 

 

 

 

compression

 

 

 

 

 

 

 

 

 

 

2h

Read Data Bytes Sent,

8

0

0

0

 

before compression

 

 

 

 

 

 

 

 

 

 

3h

Read Data Bytes Sent,

8

0

0

0

 

after compression

 

 

 

 

 

 

 

 

 

 

0100h

Cleaning Required

8

0

0

0

 

 

 

 

 

 

8000h

Megabytes processed

4

0

0

0

 

since last cleaning

 

 

 

 

 

 

 

 

 

 

8001h

Lifetime load cycles

4

0

0

0

 

 

 

 

 

 

8002h

Lifetime cleaning cycles

4

0

0

0

 

 

 

 

 

 

A non-zero value of the Cleaning Required parameter indicates that a condition requiring cleaning has been detected and a subsequent cleaning cycle has not been completed. The Cleaning Required parameter is persistent across hard resets and power cycles.

22Ultrium Internal Tape Drive and 3580 Ultrium Tape Drive: SCSI Reference

Page 36
Image 36
IBM T200F manual Sequential Access Device Log Parameters, Parameter Description Length