Remove Traps For the Remove Traps Diagnostic, the CDB values should be set as follows:
vPF-1
vSelfTest - 0
vDevOfl - Any value allowed and ignored
vUnitOfl - Any value allowed and ignored
vParameter List Length - X000A
Table98 shows the parameter data to be sent with the Remove Traps diagnostic.
If all that is desired is to inspect which Traps have been set, sending down Remove
Traps with the Fault Symptom Code set to X0000 will set up diagnostic results
showing which traps are currently set without changing the state of any traps.
Table98. Remove Traps Diagnostic Parameter Data
76543210
0 Page Code (80h)
1 Reserved
2Page Length (0006h)
3
4Diagnostic ID (0191h)
5
6 Flags(0000000b) Cartridge
Required
(0)
7 Reserved
8Fault Symptom Code
9
78 Ultrium Internal TapeDrive and 3580 Ultrium Tape Drive: SCSI Reference