Manuals
/
IBM
/
Computer Equipment
/
Personal Computer
IBM
T200F manual
Models:
T200F
T200
1
12
126
126
Download
126 pages
42.05 Kb
9
10
11
12
13
14
15
16
<
>
Error codes
Reset Drive
Receive Diagnostic Results
Command Support
Error Sense Information
How to
Power-On
Service Action
Sequential Access Device Log
Features of the Scsi Interface
Page 12
Image 12
x
Ultrium Internal Tape Drive and 3580 Ultrium Tape Drive: SCSI Reference
Page 11
Page 13
Page 12
Image 12
Page 11
Page 13
Contents
Scsi Reference
Page
Scsi Reference
Fifth Edition October
Contents
Error Sense Information
How to Send Your Comments Trademarks Index
Page
Tables
Vii
Page
Tables
Page
Preface
Organization
Page
Introduction
IBM 3580 Ultrium Tape Drive
Ultrium Internal Tape Drives feature
Scsi Attachment
Fibre Channel Attachment
Server Operating System
SUN
Supported Device Drivers
Hpux
Command Support
Supported Common Commands
Erase Command
Erase
Inquiry Command
Inquiry
Evpd
Standard Inquiry Data Valid LUN
Standard Inquiry Data Valid LUN
AENC0
NACA0
Standard Inquiry Data Invalid LUN
Standard Inquiry Data Invalid LUN
Supported Vital Product Data
Unit Serial Number
Supported Vital Product Data Inquiry
Unit Serial Number Inquiry
Device Identification
Device Identification Inquiry
Identifier Descriptor Format
Fibre Channel Identification Descriptor
Drive Component Revision Levels Pages
Drive Component Revision Levels Pages
LOAD/UNLOAD Command
LOAD/UNLOAD
Locate Command
Locate
LOG Select Command
LOG Select
LOG Sense Command
LOG Sense
Log Page Format
Log Page Header Format
Reserved Code
Log Parameter Format
Supported Log Pages
Supported Log Pages Log Page Format
Write Error Counters Log
Write Error Log Parameters
Parameter Definition Description
Read Error Counters Log
Read Error Log Parameters
Sequential Access Device Log
Sequential Access Device Log Parameters
Parameter Description Length
TapeAlert Log
Tape Usage Log
Tape Capacity Log
Parameter Description Type
Description Length
Data Compression Log
Data Compression Log Parameters
Mode Select
Byte Mode Select Command
Mode Sense
Byte Mode Sense Command
DBD
Mode Data Format
Mode Parameter Header
Mode Data Format
Mode Parameter Header 6-Byte Command
Mode Block Descriptor
Mode Block Descriptor
Read-Write Error Recovery
Read-Write Error Recovery
Disconnect/Reconnect Mode
Disconnect/Reconnect
Data Compression Mode
Data Compression Mode
Sequential Access Device Configuration
Sequential Access Device Configuration Reserved
BIS RSmk AVC Socf RBO REW Gap Size EOD Defined EEG SEW
Buffer Size at Early Warning
Fibre Channel Logical Unit Control
Fibre Channel Logical Unit Control
Fibre Channel Port Control
Fibre Channel Port Control
Dtfd Plpb
Dtipe Dtoli
Information Exceptions Mode
Information Exceptions Mode
Persistent Reserve in Command
Persistent Reserve
Persistent Reserve in Parameter Data for Read Keys
Persistent Reserve in Parameter Data for Read Reservations
Persistent Reserve in Read Reservations Descriptor
Persistent Reserve OUT Command
Persistent Reserve OUT
Persistent Reserve OUT Parameter List
Aptpl
PREVENT/ALLOW Medium Removal Command
PREVENT/ALLOW Medium Removal
Prevent
Read Command
Read
Sili
Service Action
Supported Service Action Codes
Read Attribute
First Attribute ID
Parameter Data for an Attribute List Service Action Request
Parameter Data for a Volume List Service Action Request
Available Data n-3 Attribute #1 Attribute #y
Available Data
Medium Auxiliary Memory Attribute Data
Format for Medium Auxiliary Memory Attribute
Attribute Descriptions
Attribute Name Number Format Bytes
Ascii
Device Vendor/Serial Number Attribute
Describes the Medium Common Attributes
Host Common Attributes
Read Block Limits Command
Read Block Limits
Read Block Limits Descriptor
Maximum block length limit FFFFFFh
Read Buffer Command
Read Buffer
Read Buffer Descriptor
Reserved
Drive Buffers
Supported Buffers Offset Boundary
VPD
Error Log Buffer
Error Log Buffer Command
Read Position Command
Read Position
Read Position Data
BOP
Receive Diagnostic Results
Receive Diagnostic Results Command
Byte Release Unit Command
Release Unit
Report Density Support Command
Report Density Support
Report Density Support Header
Report Density Support Descriptor Block
Wrtok
Density Information for LTO Formats
Primary density code
Secondary density code
Bits per mm
Report LUNs Command
Report LUNs
Logical Unit Numbers Data
Request Sense Command
Request Sense
Sense Data Format
Sense Data Format
EOM ILI
Sksv
Command Support
Page
Byte Reserve Unit Command
Reserve Unit
Rewind Command
Rewind
Operation Code 01h
Send Diagnostic
Send Diagnostic Command
Self-Test
SIM Data Structure
SIM Data Structure
Vendor ID IBM Plant of Manufacture Product ID3 ’-’
MIM Data Structure
MIM Data Structure
MIM Data Structure Error Code
Volume ID Flag
Vendor ID IBM Plant of Manufacture Product ID3 ’-’
Device Type
Page
Force Dump Diagnostic Parameter Data
Force Dump
Write Dump to Cartridge Send Diagnostic Parameter Data
Write Dump to Cartridge Receive Diagnostic Parameter Data
Write Dump To Cartridge
SIM/MIM
Post a Self Test Diagnostic
Post a Self Test Send Diagnostic Parameter Data
Post B Tape Test Diagnostic
Post B Tape Test Send Diagnostic Parameter Data
Post B Tape Test Receive Diagnostic Parameter Data
Post C Media Test Diagnostic
Post C Media Test Send Diagnostic Parameter Data
Post C Media Test Receive Diagnostic Parameter Data
Post D Head Test Diagnostic
Post D Head Test Send Diagnostic Parameter Data
Post D Head Test Receive Diagnostic Parameter Data
Set Traps Diagnostic Parameter Data
Set Traps
Remove Traps Diagnostic Parameter Data
Remove Traps
Reset Drive Diagnostic Results Data
Reset Drive
Reset Drive Diagnostic Parameter Data
Space Command
Space
Test Unit Ready Command
Verify Command
Test Unit Ready
Verify
Write Command
Write
Write Attribute
Write Buffer Command
Write Buffer
Write File Marks Command
Write File Marks
Error Sense Information
Sense Data
Sense Data Management
Unit Attention Conditions
Persistent Errors
Sense Keys and Additional Sense
Sense Keys and Additional Sense
Sense Key Additional Sense Explanation
ASC/ASCQ
Sense Keys and Additional Sense
ASC/ASCQ
Attachment Features
Power-On
Reset Strategy
Types of Interface Attachments
Command Abort Processing
Abort Handling
Abort Condition Handling
Receive Diagnostic
Send Diagnostic
Results Release Unit
Report Density
Description Value When returned
Multi-initiator Support
Status Codes
Status Codes
Features of the Scsi Interface
Bus Parity Errors
LUN Identification
Disconnect Strategy
Messages
Supported Outbound Messages
Name Code Support
Message
Supported Inbound Messages
Extended Messages
Supported Extended Messages
Features of the Fibre Channel Interface
Page
Appendix. Notices
103
How to Send Your Comments
Trademarks
AIX
IBM
LTO
Page
Index
107
Post C media test diagnostic Post D Head Test diagnostic
Readers’ Comments We’d Like to Hear from You
How satisfied are you that the information in this book is
Please tell us how we can improve this book
Business Reply Mail