Set Traps

For the Set Traps Diagnostic, the CDB values should be set as follows:

vPF - 1

vSelfTest - 0

vDevOfl - Any value allowed and ignored

vUnitOfl - Any value allowed and ignored

vParameter List Length - X000A

Table 97 shows the parameter data to be sent with the Set Traps diagnostic.

Table 97. Set Traps Diagnostic Parameter Data

 

7

6

5

 

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

Page Code (80h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Page Length (0006h)

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

Diagnostic ID (0190h)

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cartridge

6

 

 

 

Flags (0000000b)

 

 

 

 

Required

 

 

 

 

 

 

 

 

 

 

 

(0)

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

Fault Symptom Code

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receive Diagnostics Results: There are no diagnostic results for the Set Traps diagnostic.

Chapter 2. Command Support 77

Page 91
Image 91