Note: Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU.

This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next.

A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number.

If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to Intermittent problems.

Note: For a device not supported by diagnostic codes in the ThinkPad Notebooks, see the manual for that device.

Numeric error codes

Table 2. Numeric error codes

Symptom or error

FRU or action, in sequence

 

 

0177

System board

Bad SVP data, stop POST task—The checksum of the

 

 

supervisor password in the EEPROM is not correct.

 

 

 

 

 

0182

1.

Run ThinkPad Setup. Press F9, and Enter to load

Bad CRC2. Enter UEFI BIOS Setup and load Setup

 

the default setting. Then save the current setting

defaults.—The checksum of the CRS2 setting in the

 

by pressing F10.

EEPROM is not correct.

2.

System board

 

 

 

0183

 

 

Bad CRC of Security Settings in EFI Variable. Enter

 

 

ThinkPad Setup.

 

 

 

 

0187

System board

EAIA data access error—The access to EEPROM is failed.

 

 

 

 

0188

System board

Invalid RFID Serialization Information Area.

 

 

 

 

0189

System board

Invalid RFID configuration information area—The

 

 

EEPROM checksum is not correct.

 

 

 

 

 

0190

1.

Charge the battery pack.

Critical low-battery error

2.

Battery pack

 

 

 

0191

1.

Run ThinkPad Setup, and then save current

System Security—Invalid Remote Change requested.

 

setting by pressing F10.

 

2.

System board

 

 

 

0199

1.

Run ThinkPad Setup, and then save the current

System Security— Security password retry count

 

setting by pressing F10.

exceeded.

2.

System board

 

 

 

0251

1.

Charge the backup battery for more than 8 hours

System CMOS checksum bad— Default configuration

 

by connecting the ac adapter.

used.

2.

Replace the backup battery and run ThinkPad Setup

 

 

to reset the time and date.

 

 

0271

Run ThinkPad Setup to reset the time and date.

Real-time clock error. Check date and time settings.

 

 

 

 

 

40ThinkPad T520, T520i, and W520 Hardware Maintenance Manual

Page 48
Image 48
IBM W520, T520I manual Numeric error codes