Table 32. Removal steps of LCD unit (continued)

7

7

8 9

6

4

4

5

5

4

 

Step

Screw (quantity)

Color

Torque

 

 

 

 

 

 

 

 

 

M2 × 4 mm, wafer-head, nylon-coated (2)

Black

0.181 Nm

 

7

 

 

 

 

 

 

(1.85 kgfcm)

 

 

 

 

 

 

When installing:

Make sure that you attach the LCD connector firmly.

Make sure that you route the cables firmly and tape up in the proper positions as shown in this figure.

When you route the cables, make sure that they are not subjected to any tension. Tension could cause the cables to be damaged by the cable guides, or a wire to be broken.

Chapter 9. Removing and replacing a FRU 89

Page 97
Image 97
IBM T520I, W520 manual M2 × 4 mm, wafer-head, nylon-coated Black 181 Nm Kgfcm