SentinelRAID 170 Installation and Hardware Reference Manual

 

 

 

Parity error detected

SDRAM DIMM should be replaced.

 

 

Logical drive failure detected

Check proper installation or connection of drives (use

during boot-up

the "View and Edit SCSI drives" function to help

 

locating the problem).

 

 

 

 

 

 

System is not stable after running

1.

SCSI cable length must be within the range of

for a period of time.

 

specifications.

 

2.

Make sure terminators are properly installed.

 

3.

Power supply voltage must be within specifications.

 

4.

Check the enclosure’s inner temperature.

 

 

 

 

When using "Scan New SCSI

Remove the empty drive entry

Drive" and the desired ID is

 

 

empty, an empty drive entry

 

 

appears

 

 

 

 

 

 

 

 

The RS-232C Terminal Interface

1.

Check RS-232C cable connection.

does not work.

2.

Check if the Baud Rate settings on both ends

 

 

identical.

 

3.

Enable Terminal Emulation.

 

4.

Set “Data Routing Direct to Port” in the “

 

 

Communication Parameters.”

 

 

 

 

When choosing “Configure

“Terminal Emulation” should be enabled after all

Modem Port”, the screen is full of

modem configurations are completed.

“ Comm Buffer Overflow”.

 

 

 

 

 

 

 

 

The logical drive states

1.

“Optimization for ... I/O,” the logical drive caching

“INVALID”.

 

parameter is different from the current setting.

 

2.

Change “Optimization for ...I/O” to the opposite

 

 

setting and reset the controller.

 

 

 

 

In “View and Edit SCSI Drives”

“80Mhz” is SCSI sync frequency, not transfer rate.

or “View and Edit SCSI

 

 

Channels”, the speed is only

 

 

“80Mhz” (SCSI-320 machines),

 

 

not “320Mhz”

 

 

 

 

 

 

 

 

C-2

Problem

Page 66
Image 66
Infortrend SentinelRAID 170 320ML/sec SCSI-to-SCSI RAID Controller manual Problem