Ingersoll-Rand 80445364 manual XS1, QF1, FR1, FR2, FR3, Edv, 1ATS, 1RPS, Pto

Models: 80445364

1 172
Download 172 pages 24.21 Kb
Page 16
Image 16

14 GENERAL INFORMATION

TN, TT, IT 3+PE. 220−230V, 60Hz. 380−460V, 50Hz.

KEY

Alternative wiring for 3 phase, neutral and protective earth power supply.

XS1

Main terminals

QF1

Fan motor starter

QF1.1

Auxiliary contact

FU4, 5

Dryer fuses

FU1, 2

EDV fuses

FR1

Solid state relay

FR2

Solid state relay

FR3

Solid state relay

EDV

Electric drain valve

DR

Variable speed drive

MM

Main motor

FM

Blower motor

MC

Dryer motor

ES

Emergency stop

1ATS

High air temperature switch

1RPS

Dryer refrigeration pressure switch

PTO

Thermistor, motor winding temp.

P1, P2

Pressure transducer

DO

Dryer option

CA

Common alarm

WHT

White

RED Red

DDP Dryer discharge pressure (Dryer option)

ADP Aftercooler discharge pressure

220/230 NN Alternate wiring for 230v power supply with no neutral available.

WIRES

POWER − Black

DC CONTROL − Blue

NEUTRAL − Light blue

PROTECTIVE EARTH − Green / Yellow

NOTES

1.THE CORRECT TYPE AND RATING OF LINE INPUT FUSE MUST BE FITTED ONTO THE CUSTOMERS ISOLATOR OR BREAKER CLOSE TO THE COMPRESSOR.

FAST ACTING CLASS−J, T OR SEMICONDUCTOR TYPE, CURRENT LIMITING, INTERRUPT RATING − 200,000 AMPS RMS

SECTION

2.SIZING OF ELECTRICAL COMPONENTS NOT SUPPLIED BY INGERSOLL RAND IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR DATA PLATE, N.E.C., AND LOCAL ELECTRICAL CODES.

3.DECAL MUST CONFORM TO THE LATEST REVISION OF IR SPECIFICATION 92−8.95.