25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60/50Hz

 

IRN 30HP/ 22 kW

 

IRN 40HP / 30 kW

 

 

 

TAS

 

non−TAS

TAS

 

non−TAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal pressure

 

150

 

150

 

 

PSIG (bar)

 

(10.34)

 

(10.34)

 

 

 

 

 

 

 

 

 

 

 

Flow rate @ 150 PSIG (10.3 bar)

109

 

112

142

 

146

 

 

ACFM (m3/MIN) 1, 4

(3.09)

 

(3.17)

(4.02)

 

(4.14)

 

 

Flow rate @ 125 PSIG (8.6 bar)

120

 

125

152

 

158

 

 

ACFM (m3/MIN) 2, 4

(3.40)

 

(3.54)

(4.31)

 

(4.48)

 

 

Flow rate

125

 

130

158

 

164

 

 

@ 115 PSIG (8 bar) ACFM (m3/MIN) 3, 4

(3.54)

 

(3.68)

(4.48)

 

(4.65)

 

 

Airend discharge temperature.

 

 

228_F (109_C) Trip point

 

 

 

 

 

 

 

 

 

 

 

Ambient operating temperature

 

 

35_F (+2_C) 104_F (+40_C)

 

 

(min.) (max.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal power

 

30HP / 22kW

 

40HP / 30kW

 

 

 

 

 

 

 

 

 

 

 

Insulation class

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING SYSTEM − Air cooled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling air flow

 

 

2700ft3/min (76.5m3/min)

 

 

 

 

Maximum P in air ducts

 

 

0.25 inWg (6.4mmH2O)

 

 

 

 

Compressed air outlet T

N/A

 

15_F (8.3_C)

N/A

 

20_F (11_C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Separation volume

 

 

2.8 gallons

(10.7 Litres )

 

 

 

 

 

 

 

 

 

 

 

 

 

Coolant capacity

 

 

5.5 gallons

(21 Litres )

 

 

 

 

 

 

 

 

 

 

 

 

Weight − base mount unit

 

 

1350 lbs (612 kg)

 

 

 

 

 

 

 

 

 

 

 

 

Weight − 120 gallon Receiver mounted

 

 

1720 lbs (780 kg)

 

 

 

 

 

 

 

 

 

 

 

 

Weight − 240 gallon Receiver mounted

 

 

1891 lbs (858 kg)

 

 

 

 

 

 

 

 

 

 

 

 

Weight − 500 Litre Receiver mounted

 

 

1772 lbs (804 kg)

 

 

 

 

 

 

 

 

 

 

 

 

Weight − 750 Litre Receiver mounted

 

 

1891 lbs (858 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

DRYER ENGINEERING DATA

50 / 60Hz

Electrical protection class (std)

NEMA 1

 

(IP 20)

 

 

Factory refrigerant charge (oz/g)

45 oz

 

1.27 kg

 

 

Refigeration type

134 A

 

 

1Assuming a 6 psi (0.4 bar) pressure drop through the TAS module.

2Assuming a 9 psi (0.62 bar) pressure drop through the TAS module.

3Assuming a 10 psi (0.69 bar) pressure drop through the TAS module.

4Flow rate will decrease as DP through the TAS module increases.