X4I

COMPRESSOR #1

X01 TERMINAL

V1

1

2

3

4

5

6

Refer to the X4I Overview Drawing for the X4I Compressor 2 through 4 terminal connections

C05

 

 

 

 

 

 

M37-50

 

 

 

 

 

 

 

K1

 

 

 

 

 

 

 

Contact

 

 

 

 

 

 

 

48VAC

To 2TR Contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To 1VAC Contact

 

 

 

 

 

 

 

To 3OP Contact

 

 

 

 

 

+VDC

 

V

V

 

 

C01 VFD/fixed

 

 

 

Load Enable

 

1

SEQ CONT

 

 

 

Load/Unload

 

 

 

 

 

To 2TR Relay

2

LOAD UNL

 

 

 

P

3

GND

C03

 

 

 

NO

 

4

D11

 

 

 

OUT

To KM2 Contact

 

 

 

C

5

D12

 

 

 

 

 

 

 

 

 

 

6

+20V

 

 

C02

 

NC

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

LED 5 VFD

 

 

IN

C

 

 

LED 2 LOAD

 

 

 

 

 

 

 

NC

 

 

LED 1 SEQ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KM1 Contact

 

 

LED4 READY

 

RUN

LED3

 

KM1

0 VAC

 

 

ALARM

 

 

 

 

 

 

 

 

 

 

 

C04

 

KM3 Contact

 

 

 

 

 

RUN

 

1

 

 

 

 

 

 

 

2

 

 

 

 

READY

 

 

 

 

 

IR-PCB

 

 

 

Guidance only; connections may differ with date, model, type, variant, special, custom or concession builds. This information is intended to be used in conjunction with the compressor’s original control circuit diagram.