X4I

COMPRESSOR #1

X01 TERMINAL

V1

1

2

3

4

5

6

Refer to the X4I Overview Drawing for the X4I Compressor 2 through 4 terminal connections

C05

 

 

 

SSR UP6 40-50 SD

 

1M

TDRI

 

 

 

 

 

 

Relay

Relay

 

 

 

 

 

 

 

 

 

 

Contact

Contact

 

 

 

 

 

 

 

 

 

 

 

 

HATR

Restart TD

 

 

 

 

 

 

 

MMS

 

SS

Relay

 

 

 

 

 

E-STOP

OL

Contact

 

Contact

Contact

 

 

 

 

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

110VAC

 

 

 

 

 

 

 

 

 

 

 

+VDC

 

 

 

 

 

 

V

V

 

C01 VFD/fixed

 

 

 

 

 

 

 

Load Enable

 

 

 

 

 

To TR Relay

1

SEQ CONT

 

 

 

 

 

Load/Unload

 

 

 

 

 

To 1M Contact

2

LOAD UNL

 

 

 

 

 

 

 

 

 

 

 

 

1PS

 

 

3

GND

C03

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

4

D11

 

 

OUT

 

 

 

 

 

 

 

 

C

 

 

 

 

 

To 2M Contact

5

D12

 

 

 

 

 

 

 

6

+20V

 

C02

 

NC

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED 5 VFD

 

IN

C

 

 

 

1M

 

 

 

LED 2 LOAD

 

 

 

 

 

 

 

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

Contact

 

 

 

LED 1 SEQ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED4 READY

RUN

LED3

 

 

 

 

 

 

1M

0 VAC

 

ALARM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C04

RUN

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

READY

 

 

 

 

 

 

 

 

 

IR-PCB

 

 

 

 

 

 

 

 

Guidance only; connections may differ with date, model, type, variant, special, custom or concession builds. This information is intended to be used in conjunction with the compressor’s original control circuit diagram.

SSR UP6 40-50 SD 1of2 Page 49

Page 49
Image 49
Ingersoll-Rand X41 SSR UP6 40-50 SD 1of2, C01 VFD/fixed Load Enable To TR Relay, Load/Unload To 1M Contact