Connect - displays the Connect dialog with the server from the Phonebook's Server dropdown list box already populating the Connect dialog's Server field.

Cancel - exits the Connect dialog without taking any action.

Help - displays the help information for this dialog.

Management Plug-ins

SEL Viewer

The SEL Viewer provides access to the System Event Log on the server and can display records in either hexadecimal or text (verbose) form. Options available through the SEL Viewer are:

View the SEL from a saved file

Save the SEL to a file

View SEL summary info

View all SEL entries

View SEL entries by sensor type

View SEL entries by event type

Set SEL display mode to either Hex or verbose mode

Set the SEL output file format to either text or binary format

Close the SEL Viewer

Exit the EMP Console

SEL Viewer Menu Options

The following menu options are found on the SEL Viewer menu bar:

File

Open - views SEL data from a previously saved file if it was stored in binary format. Selecting the Open menu item allows you to specify a filename under which the data is found. If the file cannot be opened, the program displays an error message.

Close - closes the SEL Viewer.

Save - saves the SEL events to a file in either binary raw or verbose text format. The binary file may be retrieved later. Once data has been saved to a file, selecting this option will save the data to the previously saved file. If no SEL events have been retrieved, then this menu option is not available.

Save As - saves the SEL events to a new file in either binary raw or verbose text format. The binary file may be retrieved later. Selecting this option lets you specify a filename to which the data will be saved. If no SEL events have been retrieved, then this menu option is not available.

Exit - exits the EMP Console.

View

SEL Information - displays SEL summary information as returned by the server.

All Events - displays all events in the SEL.

By Sensor Type - displays all events in the SEL generated by a specific sensor type such as voltage, temperature, etc. A submenu lets you select the sensor type to be displayed.