PROCEDURE 7

RETAINING STRAP

R E T A I

This Procedure Includes the Following:

Replacing Battery Box Retaining Strap

WARNING

AfterANYadjustments,repairorserviceandBEFORE use, make sure all attaching hardware is tightened securely - otherwise injury or damage may result.

9.Feed the NEW battery box retaining strap through the slot on the INSIDE of the battery box tray.

NOTE: The NEW battery box retaining strap should pass UNDER the battery box tray.

10.Feed the NEW battery box retaining strap through the slot on the OUTSIDE of the battery box tray.

N

I

N G

S T R A P

REPLACING BATTERY BOX RETAINING STRAP (FIGURE 1)

1.If necessary, remove the front and rear shrouds. Re- fer to REMOVING/INSTALLING SHROUDS in PRO- CEDURE 9 of this manual.

2.Remove the battery boxes from the wheelchair. Re- fer to INSTALLING/REMOVING BATTERY BOXES in PROCEDURE 11 of this manual.

3.Feed the EXISTING battery box retaining strap through the male end of the retaining strap clip (DETAIL "A").

4.FeedtheEXISTINGbatteryboxretainingstrapthrough the slot on the OUTSIDE of the battery box tray.

5.FeedtheEXISTINGbatteryboxretainingstrapthrough the slot on the INSIDE of the battery box tray.

6.Feed the EXISTING battery box retaining strap through the slot at the TOP of the bracket on the battery box tray.

7.Remove the EXISTING battery box retaining strap.

8.Feed the NEW battery box retaining strap through the slot at the TOP of the bracket on the battery box tray.

Top Slot (STEP 6, STEP 8)

Bracket

Inside Slot

(STEP 5, STEP 9)

WARNING

The retaining strap MUST be fed through the male endofthebatteryboxretainingstrapclipasshown in DETAIL "A" of FIGURE 1. Otherwise, batteries will not be secured in place properly resulting in injury to the user and/or damage to the wheelchair.

11.Feed the NEW battery box retaining strap through the male end of the retaining strap clip (DETAIL "A").

NOTE: Strap should have 3/4-inch length minimum beyond buckle.

12.Install the battery boxes onto the wheelchair. Refer to INSTALLING/REMOVINGBATTERYBOXESinPRO- CEDURE 11 of this manual.

WARNING

The Battery Box Retaining Strap MUST be fastened securely and adjusted properly to hold battery boxes in place before using the wheelchair. Oth- erwise, injury to the user and/or damage to the wheelchair may occur.

13.If necessary, install the front and rear shrouds. Refer to REMOVING/INSTALLING SHROUDS in PROCE- DURE 9 of this manual.

DETAIL "A"

Male End of

Retaining Strap

Clip (STEP 3,

STEP 11)

Battery

Outside Slot (STEP 4, STEP 10)

 

Box Tray

 

 

Retaining Strap Passes Under Battery Tray

NOTE: Tray shown by itself for clarity. There is no need to remove the tray from the wheelchair if the retaining strap is being replaced.

FIGURE 1 - REPLACING BATTERY BOX RETAINING STRAP