Page 25

Installation

5.2.3Camera Link Cable

The 26CL-02-26 cable assembly has been standardized as the Camera Link cable. This cable has a 26- pin connector on both ends. This is a straight-through cable and the pin-out configuration is shown in Table 2 on page 24. Contact JAI for cable lengths other than 2 meters.

FIGURE 39. 3M Camera Link Cable

26 Position

 

26 Position

High Density

Cable

High Density

Mini D Ribbon

 

Mini D Ribbon

(MDR) Male Plug

 

(MDR) Male Plug

14 15 16 17 18 19 20 21 22 23 24 25 26

1 2 3 4 5 6 7 8 9 10 11 12 13

1 2 3 4 5 6 7 8 9 10 11 12 13

14 15 16 17 18 19 20 21 22 23 24 25 26

2X

2X

Thumbscrews

Thumbscrews

Note: For CL versions, serial communication for camera control is accomplished by means of the Camera Link connector on the rear panel of the camera.

5.2.4Power Supplies and Power Cable Setup

5.2.4 (a) Power Supplies

The TM-4200CL camera requires 12V DC power that is obtained through the 12-pin connector located on the rear panel of the camera. JAI recommends the following power supplies:

PD-12UU

100-240V AC/12V DC

1.2A universal voltage power supply,

 

 

US Plug

PD-12UUP

PD-12UU with12-pin connector

US plug

PD-12UE

PD-12UU

European plug

PD-12UEP

PD-12UU with 12-pin connector

European plug

For users providing power through the 12-pin connector, the PD-12P, PD-12UEP and PD-12UUP power supplies are available with the 12-pin mating connector already attached to the leads from the power supply. The PD-12UU and PD-12UE power supplies can be connected to the JAI power cable by means of a terminal strip or directly.

When wiring the PD-12UU and PD-12UE power supplies directly, please note the following:

The lead ends must be twisted together and tin-soldered for strength and electrical continuity.

Use shrink tubing or a similar insulator to prevent exposed leads from touching and shorting.

TM/TMC-4200CL Series Progressive Scan Cameras

Page 35
Image 35
JAI TM/TMC-4200CL operation manual Installation Camera Link Cable, Power Supplies and Power Cable Setup