JAI TM/TMC-4200CL operation manual Lookup Table, Channel Balance, Vsub

Models: TM/TMC-4200CL

1 70
Download 70 pages 62.21 Kb
Page 59
Image 59

 

 

 

 

 

 

Page 49

 

 

 

 

 

 

Serial Communication Kit

 

 

 

 

 

 

 

 

 

 

 

Command

 

Parameter

End of

Ack. Response

Description

 

 

 

 

Cmd

 

 

 

 

 

 

 

 

 

 

Gain and Offset Continued

 

 

 

 

 

 

 

 

 

 

 

 

 

:VRB=

 

XXX

<cr>

:o<cr>

Set R channel Fine Offset

 

 

 

 

 

 

 

 

(XXX = 000 - FFF)

 

 

 

 

 

 

 

 

 

 

:MGA?

 

 

<cr>

:oMG[XXX]<cr

Inquire Master Gain

 

 

 

 

 

 

 

>

(XXX = 000 - FFF)

 

 

 

 

 

 

 

 

 

 

:MGB?

 

 

<cr>

:oSG[XXX]<cr>

Inquire R channel Fine Gain

 

 

 

 

 

 

 

 

(XXX = 000 - FFF)

 

 

 

 

 

 

 

 

 

 

:VRA?

 

 

<cr>

:oMF[XXX]<cr>

Inquire Master Offset

 

 

 

 

 

 

 

 

(XXX = 000 - FFF)

 

 

 

 

 

 

 

 

 

 

:VRB?

 

 

<cr>

:oSF[XXX]<cr>

Inquire R channel Fine Offset

 

 

 

 

 

 

 

 

(XXX = 000 - FFF)

 

 

 

 

 

 

 

 

 

 

 

Lookup Table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:LINR

 

 

<cr>

:o<cr>

Set linear table

 

 

 

 

 

 

 

 

 

 

 

:GM45

 

 

<cr>

:o<cr>

Set gamma .45 table

 

 

 

 

 

 

 

 

 

 

 

:KNEE=

 

X1Y1X2Y2

<cr>

:o<cr>

Set knees

 

 

 

 

 

 

 

 

(X1, Y1, X2, Y2 = 00 - FF)

 

 

 

 

 

 

 

 

 

 

:NLUT

 

X

<cr>

:o<cr>

Set Positive Knee or Negative

 

 

 

 

 

 

 

 

Knee (X = 0 Positive, X = 1

 

 

 

 

 

 

 

Negative)

 

 

 

 

 

 

 

 

 

 

:LUT?

 

 

<cr>

:o[lut]<cr>

Inquire current LUT setting

 

 

 

 

 

 

 

 

 

 

 

Channel Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

:EABL

 

 

<cr>

:oAB0<cr>

Enable Gain Balancing

 

 

 

 

 

 

 

 

 

 

 

:DABL

 

 

<cr>

:o<cr>

Disable Gain Balancing

 

 

 

 

 

 

 

 

 

 

 

:ABL?

 

 

<cr>

:oAB[X]<cr>

Check Gain Balancing Status

 

 

 

 

 

 

 

 

(X = 1 Enable, X = 0 Disable)

 

 

 

 

 

 

 

 

 

 

:ACL=

 

X

<cr>

:o[AC][X]<cr>

Enable/Disable Optical Black Bal-

 

 

 

 

 

 

 

 

ancing and Inquire Status

 

 

 

 

 

 

 

(X = 0 Disable, X = 1 Enable,

 

 

 

 

 

 

 

X = ? Inquire Status)

 

 

 

 

 

 

 

 

 

 

 

Vsub

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:DCI=

 

XXX

<cr>

:o<cr>

Set Vsub (XXX = 600 - D00)

 

 

 

 

 

 

 

 

 

 

 

:DCI?

 

 

<cr>

:oDC[XXX]<cr>

Inquire Vsub (XXX = 600 - D00)

 

 

 

 

 

 

 

 

 

 

 

TM/TMC-4200CL Series Progressive Scan Cameras