Page 37

Functions and Operations

FIGURE 53. Sub-sampling Digital Zoom 4x

TABLE 3.

Scan Area Start Points

 

 

 

 

 

 

 

 

 

 

 

 

Scan Area

Start Point

Effective Area

Frame Rate

 

 

(Line)

(Lines x Pixels)

Dual Tap

Single Tap

 

 

 

 

 

 

 

 

 

 

 

A

Full Scan

1

2048 x 2048

14.79

8.04

 

 

 

 

 

 

 

 

B

Centered 1000

525

1000 x 2048

27.97

15/20

 

Lines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

Centered 500

775

500 x 2048

49.63

26.97

 

Lines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

Centered 250

901

250 x 2048

79.92

43.43

 

Lines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

Full Scan 2x2

1

1024 x 1024

26.42

15.09

 

Binning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

Sub-sampling

 

512 x 512

31.98

20.40

 

Digital Zoom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

Programma-

1 - 2048

1-2048 x 2048

 

 

 

ble Scan Area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 