Graphical User Interface

FIGURE 13. Trigger mode uses a manual or sensor command to operate the shutter.

FIGURE 14. To use Programmable shutter speed, select Programmable:

3.3.2 (b) Expo (lines)

The Expo (lines) selection of the Exposure Control frame determines how long the shutter remains open, since a certain amount of time is allotted to expose each line. A minimum of one line of pixels must be exposed. The maximum number of lines is 2079 in Trigger mode. Continual mode is limited to the size of the frame. Enter the number of lines desired either by clicking on the arrows in the interface, or by inputting a number directly into the box beside the “Expo (lines)” box.

3.3.2 (c) Scan Area

Changing the scan area affects the image resolution. If desired, the size of the scan area can be selected from the drop-down list box. When the Scan Area setting is used to designate the number of lines, the rest of the Exposure Control frame is disabled.

Dual-Tap TM-4200CL AccuPiXEL Series Camera-Control Software

Page 20
Image 20
JAI TM/TMC-4200CL operation manual Scan Area