Jenn-Air W10394575A Location Requirements, Mobile Home - Additional Installation Requirements

Models: W10394575A

1 64
Download 64 pages 25.53 Kb
Page 4
Image 4
Location Requirements

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located under the console on the right-hand side.

It is recommended that a 600 CFM or larger range hood be installed above the range.

It is not recommended that a microwave hood combination be mounted above the range.

Recessed installations must provide complete enclosure of the sides and rear of the range.

To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.

All openings in the wall or floor where range is to be installed must be sealed.

Do not seal the range to the side cabinets.

Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.

The anti-tip bracket must be installed. To install the anti-tip bracket shipped with the range, see “Install Anti-Tip Bracket” section.

Grounded electrical supply is required. See “Electrical Requirements” section.

Proper gas supply connection must be available. See “Gas Supply Requirements” section.

Contact a qualified floor covering installer to check that the floor covering can withstand at least 200°F (93°C). Use an insulated pad or ¼" (0.64 cm) plywood over carpet and under range if installing range over carpeting.

IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.

In Canada, the installation of this range must conform with the current standards CAN/CSA-A240-latest edition, or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

Product Dimensions

30" (76.2 cm) models

A

B

C

E

D

A. Island trim

B. 27¾" (70.5 cm) depth with control panel, see NOTE*

C. 35¾" (89.6 cm) cooktop height when setting on the wheels D. 30" (76.2 cm) width

E. Model/serial rating plate location

36" (91.4 cm) models

A

B

C

E

D

A. Island trim

B. 27¹⁄₈" (68.9 cm) depth with control panel, see NOTE*

C. 35¾" (90.2 cm) cooktop height when setting on the wheels D. 36" (91.4 cm) width

E. Model/serial rating plate location

4

Page 4
Image 4
Jenn-Air W10394575A Location Requirements, Mobile Home - Additional Installation Requirements, 36 91.4 cm models