John Lewis JLBIDU712 Installation, Combined with appliances from the same manufacturer

Models: JLBIDU712

1 40
Download 40 pages 51.91 Kb
Page 34
Image 34

Installation

The set-up of the electrical installation is arranged so that the appliance can be isolated from the mains with a minimum 3

mm all-pole contact separation. Suitable isolation devices include, for example, circuit breakers, fuses (screw type fuses are to be removed from the holder), RCDs and contactors.

Anti-shock protection must be provided by the installation.

The built-in unit must meet the stability requirements of DIN 68930.

Built-in cookers and cooking surfaces are equipped with special attachment systems. For safety reasons, they must only be

combined with appliances from the same manufacturer.

The use of heat protection strips is prohibited for cookers and ovens with Pyrolytic Cleaning, if the recess has a rear wall and closed ground-level compartment. However installation is possible with a ground-level compartment that has been shortened by at least 20 mm and which has base ventilation of the same cross-section.

40mm

320mm

320 mm

90°

90°

364 mm

551 mm

720 mm

560 mm

34

Page 34
Image 34
John Lewis JLBIDU712 instruction manual Installation, Combined with appliances from the same manufacturer