Chapter 3: Installation

3.2INSTALLING THE 6H122-16 INTO THE 6C105 CHASSIS

Failure to observe static safety precautions could cause

!damage to the 6H122-16. Follow static safety handling rules

CAUTION

and properly wear the antistatic wrist strap provided with the

 

 

6C105 chassis.

Do not cut the non-conductive bag to remove the module.

!Damage could result from sharp objects contacting the board

CAUTION

or components.

 

The 6H122-16 can be installed in any of the 5 slots that are available. To install a module, proceed as follows:

1.Remove the blank panel covering the slot in which the module will be installed. All other slots must remain covered to ensure proper airflow and cooling. (Save the blank plate in the event you need to remove the module.)

2.Carefully remove the module from the shipping box. (Save the box and packing materials in the event the module must be reshipped.)

3.Locate the antistatic wrist strap shipped with the 6C105 chassis. Attach the strap to your wrist and plug the cable from the antistatic wrist strap into the ESD grounding receptacle at the upper right corner of the 6C105.

4.Remove the module from the plastic bag. (Save the bag in the event the module must be reshipped.) Observe all precautions to prevent damage from Electrostatic Discharge (ESD).

5.Examine the module for damage. If any damage exists, DO NOT install the module. Immediately contact the Cabletron Systems Global Call Center.