Chapter 5: Local Management

Current Switch Utilization (Read-only)

Shows how much (percentage of capacity) the 6H122-16 is currently being used.

Peak Switch Utilization (Read-only)

Shows the peak percentage of maximum switching capacity, since last reset.

Reset Peak Switch Utilization (Toggle)

Allows the user to reset the Peak Switch Utilization field. The switch may be set to either YES or NO as described in Section 5.21.1. YES resets the Peak Switch Utilization field to the current system traffic.

5.21.1 Setting the Reset Peak Utilization

To reset the Reset Peak Utilization field counter, proceed as follows:

1.Use the arrow keys to highlight the Peak Switch Utilization field.

2.Press the SPACE bar to select YES.

3.Use the arrows keys to highlight the SAVE command at the bottom of the screen.

4.Press ENTER. The message “SAVED OK” is displayed, and the Reset Peak Utilization counter is reset to zero.

5.22FLASH DOWNLOAD SCREEN

The Flash Download screen, shown in Figure 5-31, allows the user to clear the information stored in the 6H122-16 FLASH memory and download a new image file from a TFTP server.

NOTE

The user may also force a download by changing the position of Switch 6 located inside the module. Refer to Section B.2 for details.

Before downloading a new image to the module, load the image onto the network TFTP server.

NOTE

For information on how to set up a workstation as a TFTP server, refer to the specific workstation documentation.

5-74

6H122-16 User’s Guide

Page 114
Image 114
Cabletron Systems 6H122-16 manual Setting the Reset Peak Utilization, Flash Download Screen