Switch definitions and positions are as follows:

Appendix B: Mode Switch Bank Settings

Figure B-1shows the location of the mode switches and the switch settings for normal operation.

Flash

DRAM

MODE SWITCH

OFF ON

1

2

3

4

5

6

7

8

2361_34

Figure B-1 6H122-16 Mode Switch Location/Component Layout

Switch definitions and positions are as follows:

Switches 1 through 4 – For Cabletron Systems use only.

Switch 5 – COM Port Autobaud. The default (OFF) position enables Autobaud sensing on the COM port for Local Management sessions. Changing the switch to the ON position disables Autobaud sensing and sets the COM port to 9600 baud for Local Management sessions.

Switch 6 – Forced BootP. Changing the position of this switch (i.e., moving the switch from one position to the other) clears download information from NVRAM and forces the 6H122-16 to download a new image file from a BootP server after power to the chassis is restored.

NOTE

After changing the position of switch 6, DO NOT reapply power to the chassis until there is a station acting as a BootP server, which contains the image file.