Time Since Peak (Read-Only)

Chapter 5: Local Management

Time Since Peak (Read-Only)

Displays the time since peak broadcast frames received.

Threshold (Modifiable)

Allows the user to set the desired limit of receive broadcast frames that will be forwarded per port per second.

Reset Peak (Toggle)

Allows the user to reset the peak rate. Resetting the Peak Rate also resets the Time Since Peak field. The Reset Peak field toggles between YES and NO.

[1-12], or [13-16] (Navigation Field)

When the Broadcast Statistics screen displays, the current statistics are displayed for the first 12 ports. This field allows the user to step to a second screen for the same type of information for ports 13 through 16. While on the second screen, the user can navigate back to the first screen by selecting the [1-12]field. This is accomplished by using the arrow keys to highlight the field, and then pressing ENTER. The user can change the Threshold or Reset Peak Rate fields while in the first or second screens.

5.24.1 Setting the Threshold

To set the Threshold, proceed as follows:

1.Use the arrow keys to highlight the Threshold field for the selected port.

2.Type in the numbers for the desired limit in increments of 10.

3.Use the arrow keys to highlight the SAVE command at the bottom of the screen.

4.Press ENTER. The message “SAVED OK” is displayed.

5.24.2 Setting the Reset Peak Switch

To reset the Reset Peak Switch counter to zero, proceed as follows:

1.Use the arrow keys to highlight the Reset Peak field for the selected port.

2.Press the SPACE bar to select YES.