Troubleshooting Checklist

4.2TROUBLESHOOTING CHECKLIST

If the 6H122-16 is not working properly, refer to Table 4-3for a checklist of possible problems, causes, and recommended actions to resolve the problem.

Table 4-3 Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

 

 

 

 

 

 

All LEDs are OFF.

Loss of Power to the 6C105

Check the proper

 

chassis.

connection of the power

 

 

cable and its access to a

 

 

live outlet.

 

 

 

 

The 6H122-16 not properly

Check the installation. Refer

 

installed.

to Chapter 3.

 

 

 

No Local

Autobaud enabled, but baud

Press ENTER (RETURN)

Management

rate has not been detected.

(may take up to four times).

Password screen.

 

 

Terminal setup is not

Refer to Chapter 5 for

 

 

correct.

proper setup procedures.

 

 

 

 

Improper console cable

Refer to Appendix A for

 

pinouts.

proper console port pinouts.

 

 

 

Cannot contact the

Improper Community

Refer to Section 5.8

6H122-16 from

Names Table.

for Community Names

in-band

 

Table setup.

management.

 

 

The 6H122-16 does not

Refer to Section 5.15.1 for

 

 

have an IP address.

IP address assignment

 

 

procedure.

 

 

 

 

Port is disabled.

Enable port.

 

 

 

 

No link to device.

Check link to device.

 

 

 