<Functions controlled by the MAKE/TRIGGER system>
Display | Functions to be controlled | Opening |
| |
TALLY SEL | Selects the color of the tally lamp | Green |
| Red |
|
|
|
|
|
SDI 1 | Changes the input to “SDI 1” | Invalid |
| Valid |
SDI 2 | Changes the input to “SDI 2” | Invalid |
| Valid |
DVI | Changes the input to “DVI” | Invalid |
| Valid |
Display | Functions to be controlled | Invalid |
| Valid |
COMPO. | Changes the input to “COMPO.” | Invalid |
| Valid |
VIDEO | Changes the input to “VIDEO.” | Invalid |
| Valid |
Selects the data stream of “3G SDI LEVEL B” | DS1 |
| DS2 | |
DUAL LINK | Turns on or off “SDI DUAL LINK” | Off |
| On |
A.MARKER | The area marker indication | Off |
| On |
S.MARKER | The safety marker indication | Off |
| On |
FRAME | Indication of the area of the specified aspect ratio | Off |
| On |
C.MARKER | The center marker indication | Off |
| On |
MARK.SEL | Selects the items of “MARKER” *3 |
| ||
ASPECT | Changes the aspect ratio | 4:3 |
| 16:9 |
1:1 | Displays in 1:1 mode | Off |
| On |
STATUS | Status display *4 | ☞ “On the Status Display” on page 12 | ||
L.METER | Audio level meter display |
| *5 | |
TIME CODE | Time code display | Off |
| On |
SOURCE ID | ☞ “SOURCE ID” in “INFORMATION” on page 21 |
| *6 | |
WAVE FORM | Displays the wave form monitor (Normal or Difference) |
| *7 | |
VECTOR | Displays the vector scope |
| ||
|
|
| ||
COLOR OFF | Color off | Color |
| Monochrome |
SCR CHECK | Screens check |
| *8 | |
I/P MODE | Change a mode according to the input picture |
| *9 | |
MUTING | Muting on/off | Off |
| On |
DIMMER | Change the intensity of the button lamps | NORMAL |
| DARK |
−−− | No function | — |
| — |
*3 | Selects which functions in “MARKER” are activated, |
*4 | Displays the information shown when INPUT SELECT button of the current input is pressed (☞ “On the Status Display” on page 12). While controlling |
| with the MAKE system, the information is displayed only at the moment of |
*5 | While controlling with the MAKE system, the level meter is switched between displayed |
| ch” is set to “OFF,” the level meter is not displayed (“NO EFFECT” appears). While controlling with the TRIGGER system, the pattern of the audio |
| channel display is switched. |
*6 | While controlling with the MAKE system, the available |
| |
| “SOURCE ID” in “INFORMATION” on page 21). |
*7 | While controlling with the MAKE system, the wave form monitor and vector scope is switched between displayed |
| (opening) regardless of the “AUTO OFF” setting in the MAIN MANU. While controlling with the TRIGGER system, the screen is switched in the same |
| way as when pressing the SCOPE button (☞ e on page 10). If the wave form monitor and vector scope are input at the same time, the wave form |
| monitor is displayed. |
*8 | While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue screen |
| controlling with the TRIGGER system, the screen changes in the same way as when pressing SCREENS CHECK button (☞ q on page 10). |
*9 | Must be controlled with the TRIGGER system. The mode changes in the order of “NORMAL” \“CINEMA” \“FIELD” (This function cannot be |
| controlled with the MAKE system). |
●You cannot assign the same function to different pin terminals.
●The TRIGGER system switches each function by
23