<Basic command list>
No.

 

 

 

 

 

 

 

Commands

 

 

 

 

Functions

Data

1

!

*

**1

B

C

N

1

Cr

 

 

 

 

 

 

Starts communication (connection)

No data

2

!

*

**1

B

C

N

0

Cr

 

 

 

 

 

 

Terminates communication (termination)

No data

3

!

*

**1

B

I

D

S

E

T

x

x*2

Cr

 

 

Assigns the control ID

 

 

01 – 99

4

!

*

**1

B

I

D

R

E

T

Cr

 

 

 

 

Initializes the control ID

 

 

No data

5

!

*

**1

B

I

D

D

S

P

x

x*2

Cr

 

 

Displays/hides the ID

 

 

00: Hide

 

 

 

 

01: Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

!

*

**1

B

I

D

C

H

K

x

x*2

Cr

 

 

Flashes/hides the selected ID No. of the monitor

00: Hide

 

 

01: Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

!

*

**1

B

M

E

N

U

Cr

 

 

 

 

 

Displays the MAIN MENU/Quits the menu operation

No data

8

!

*

**1

B

U

P

Cr

 

 

 

 

 

 

 

Moves the cursor downward (

)

No data

9

!

*

**1

B

D

O

W

N

Cr

 

 

 

 

 

Moves the cursor downward (

)

No data

10

!

*

**1

B

A

D

J

R

Cr

 

 

 

 

 

Makes setting/adjustment (

)

 

No data

11

!

*

**1

B

A

D

J

L

Cr

 

 

 

 

 

Makes setting/adjustment (

)

 

No data

12

!

*

**1

B

S

E

T

U

P

Cr

 

 

 

 

Displays the SET-UP MENU

 

 

No data

13

!

*

**1

B

P

W

1

Cr

 

 

 

 

 

 

Turns on the monitor

 

 

No data

14

!

*

**1

B

P

W

0

Cr

 

 

 

 

 

 

Turns off the monitor (on standby)

No data

15

!

*

**1

B

I

N

A

Cr

 

 

 

 

 

 

Selects “SDI 1” input

 

 

No data

16

!

*

**1

B

I

N

B

Cr

 

 

 

 

 

 

Selects “SDI 2” input

 

 

No data

17

!

*

**1

B

I

N

C

Cr

 

 

 

 

 

 

Selects “DVI” input

 

 

No data

18

!

*

**1

B

D

I

S

P

Cr

 

 

 

 

 

Displays the status *3

 

 

No data

19

!

*

**1

B

A

M

U

T

E

x

x*2

Cr

 

 

Turns muting on/off

 

 

00: Off

 

 

 

 

01: On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

!

*

**1

B

A

S

P

x

x*2

Cr

 

 

 

 

Changes the aspect ratio

 

 

00: 4:3

 

 

 

 

 

 

01: 16:9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

!

*

**1

B

R

O

P

O

S

I

x

x

x

x*2 Cr

Configures POSITION settings

 

−999 – +999

22

!

*

**1

B

R

O

P

U

S

H

x

x*2

Cr

 

Configures PUSH SEL. settings

 

00: Change selection,

 

 

01: Reset the position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

!

*

**1

B

S

E

L

E

C

T

Cr

 

 

 

Operates the SELECT keys

 

 

No data

“Cr” is 0Dh.

The commands for starting communication (connection) (No. 1), terminating communication (termination) (No. 2), and turning on the monitor (No. 13) can be used while the monitor is off (on standby).

*1

Enter the monitor’s ID for “**.” The initial setting of the monitor’s ID is “00.” When connecting several monitors, “00” is a command for controlling all

 

monitors at once.

*2

Enter the appropriate data to “xx.”

*3

Displays the information shown when the INPUT SELECT button currently lit is pressed (“On the Status Display” on page 12).

25