Connecting the control signal cable

Connecting the control signal cable

(Use a twisted-pair cable for connection.  Page 17.)

Camera 1 control signal connection terminals

TX+ A

TX B

RX+ C

RX D

Camera 2 control signal connection terminals

TX+ A

TX B

RX+ C

RX D

RM-P2580

A RX +

BRX

CTX +

DTX

Connect:

Camera TX+ to RM-P2580 RX+ Camera TX– to RM-P2580 RX– Camera RX+ to RM-P2580 TX+ Camera RX– to RM-P2580 TX–

The A B C D marks indicated on both the camera terminals and the RM-P2580 termi- nals facilitate correct connections. Connect the terminals with identical marks.

Setting the switches (

 

 

 

 

EXT TERM-OFF

 

 

 

 

INT/GL

SET

CAMERA

 

 

DUPLEX

AWC

SETUP

EXT TERM-OFF

ON

RX TERM-OFF

MENU

 

DUPLEX

SIMPLEX

 

INT/GL

LL

 

 

 

RX TERM-OFF

ON

 

 

 

NOT USED

 

NOT USED

 

 

 

 

 

 

 

VIDEO

IRIS

 

 

 

 

 

 

 

DC

 

Page 10)

Select the synchronization method of the camera image.

Set the switch on all cameras to LL (Line Lock) and match with the V. PHASE.

( Page 26.)

ON

LLSet this switch to the DUPLEX

SIMPLEX* If the setting is changed, be absolutely sure to

ON

switch on the power again.

Set this switch to ON (signal termination ON) only on the camera placed at the end of the control signal cable.

Set to OFF on all other cameras.

Setting on the MENU screen ( Page 35)

* If the setting is changed, escape from the menu screen once, and definitely switch on the power again.

C OMMUN I C A T I O N

 

S T Y L E

M . DROP

MACH I N E I D

1

Set to M.DROP

Set to M.DROP when the RM-P2580 is used as a remote control unit. When controlling from another machine, make sure that it matches the communication system used.

MACHINE ID setting switches

Set this item to match the RM-P2580 VIDEO INPUT terminal number for each camera.

When connecting

Turn OFF the power supply to all equipment to be used before making connections.

Carefully read the Instructions for each piece of equipment to be used before making connections.

For the appropriate connection cables and the length of these, carefully read “Connections on the back” on page 16.

The control signal cable cannot be used for loop connection.

E-13

Page 13
Image 13
JVC TK-C1460 manual E-13,  Connecting the control signal cable,  Setting the switches , Page, When connecting