Data transfer from receiver to receiver

Your receiver is able to receive the RS232C socket data from another receiver. To do so, both receivers must be connected via a so-called 'zero modem cable.' The transmitting receiver is in this case the master and the receiving receiver is the slave.

Preparation

The master and slave are first switched to standby mode and then disconnected from the mains by pressing the power switch.

The data sockets of both receivers are connected with the zero modem cable.

The master is then switched on again.

Transferring programme lists

Simultaneously press the ￿￿button (arrow left) and “SELECT” under the front panel of the master to transfer the channel list.

The slave can now be switched on. The transfer procedure begins.

While loading, the display of the master shows "t001 t002 .. t00n“ while the slave correspondingly shows "r001 r002..r00n“.

The LED display shows "----" during block transmission.

The loading procedure was successful, if both receivers show the message "Succ."

Transferring operating software

Follow the same procedure as described above for the purpose of transferring operating software.

Start transfer of the operating software by simultaneously pressing the ￿￿button (arrow right) and “SELECT” under the front panel of the master.

While loading, the display of the master shows "t001 t002 .. t00n“ while the slave correspondingly shows "r001 r002..r00n“.

The LED display shows "----" during block transmission.

The loading procedure was successful, if both receivers show the message "Succ." Should transfer problems occur, "F * * *" will appear in the master display where * stands for a numerical value. In this case, check the cable connection and start a new transfer attempt.

The data transfer from receiver to receiver as described above must only be carried out with devices of the same type as otherwise malfunctions or total loss of the operating software may occur.

On no account must the receivers be switched off or the connection interrupted during data transfer. This may otherwise result in data loss, malfunctions or total failure of the operating system.

Always wait until the "Succ." or "F * * *“ message appears on the display.