SERVICETECH. INFORMATION
SECTION 5
26
5C.. WATERFLOWTHROUGHTHE SOFTENERVALVE

SERVICECYCLE

Hardwaterentersthevalveinletport.Internalvalveportingroutesthe
waterdownandout thetop distributor,intotheresintank.Hardwateris
softenedas itpassesthroughtheresinbed,thenentersthebottom
distributor.Softwaterflowsbackintothevalveandout thevalveoutlet,to
thehousesoft waterpipes.
ToValve Outlet
(soft water)
resin
bed resin
bed
bottomdistributor
resintank
top distributor
fromValveInlet
(hardwater)
position
switch

FILL CYCLE

Tobeginaregeneration,the electronictimerenergizesthecircuit tothevalve
motor.Thevalvemotorrotatestherotorand discandthevalvecamuntil the
positionswitchleverdrops,toopenthemotorcircuitand positionthevalvein
FILL.Astherotoranddiscrotates,theportopensforSOFTwaterfill through
theventuri.Fill flowcontinuestothebrinevalve,andintothesaltstorage
tank.Soft wateris still availabletothehouselines.
ToValve Outlet
(soft water)
resin
bed resin
bed
bottomdistributor
resintank
top distributor
fromValveInlet
(hardwater)
fill water
(soft)
fill flow
plug
venturi
position switchvalvecam
rotor&disc
position
switch