Remote control unit

Symptom

Remedy

Remote control operation is not possible.

=Replace batteries with new ones (page 6).

=If the remote is too far away from the system or there is an obstacle in between, point the remote to the remote sensor on the main unit.

MD recorder section (Symptoms related to the MD standard)

Symptom

Remedy

The recordable time of the disc does not increase even when a short track is erased.

=When the remaining time of the entire disc is less than 12 sec., the remaining recordable time does not increase.

=When the disc has been edited several times, the re- maining recordable time may not increase.

Tracks cannot be combined. = When the disc has been edited several times, the tracks may be unable to be combined.

The total of the recorded time and = As the minimum unit of disc recording is 2 seconds, the

remaining recordable time does not displayed time information may differ from the actual

coincide with the recording time usage of the disc area. specified for the MD.

Sound is interrupted after forward = When the disc has been edited several times, the sound

or reverse search.

may be intermittent.

"READING" is displayed for an abnormally long time.

=When a new recordable MD (with nothing recorded) is inserted, "READING" is displayed longer than usual.

MD recorder section

Symptom

Remedy

 

 

Sound is not output even when

= Use a recorded MD.

the play key is pressed.

 

Recording is not possible.= Restore the position of the write protect tab to the write enabled position. (page 53)

=Select the input source to be recorded. (page 27)

CD player section

Symptom

Remedy

 

 

Sound it not produced even when the play key is pressed.

=Insert the CD properly (page 12).

=Clean the disc as described in "Disc handling precautions" (pages 52 and 53).

=Remove condensation as described in "Caution on con- densation" (page 52).

Sound skips.

= Clean the disc as described in "disc handling precautions"

 

(pages 52 and 53).

 

= Check that the disc is not scratched.

 

= Install the unit in a place not subject to vibrations.

 

 

56 EN