Kenwood TK-270G service manual TK-260G/270G, Realignment, No. Function

Models: TK-270G

1 50
Download 50 pages 29.94 Kb
Page 14
Image 14
No. Function

TK-260G/270G

REALIGNMENT

No. Function

Choices

Display

Remarks

4 [ ]TK-270G

Group Up

KEY2_25

 

 

 

 

only

Scrambler

KEY2_26

Only when scrambler is set

5 [2]TK-270G

No Function KEY3_OFF

 

only

Talk Around KEY3_3

Default

 

Display Character

KEY3_5

 

 

Home Channel KEY3_7

 

 

Channel Down KEY3_8

 

 

Channel Up KEY3_9

 

 

Keylock

KEY3_10

 

 

Lamp

KEY3_11

 

 

Selectable QT

KEY3_15

M destination only

 

Monitor A

KEY3_17

 

 

Monitor B

KEY3_18

 

 

Monitor C

KEY3_19

 

 

Monitor D

KEY3_20

 

 

RF Power Low KEY3_21

Default

 

Scan

KEY3_22

 

 

Scan DEL/ADD

KEY3_23

 

 

Group Down KEY3_24

 

 

Group Up

KEY3_25

 

 

Scrambler

KEY3_26

Only when scrambler is set

6 [3]TK-270G

No Function KEY4_OFF

 

only

Talk Around KEY4_3

 

 

Display Character KEY4_5

 

 

Home Channel KEY4_7

 

 

Channel Down KEY4_8

 

 

Channel Up KEY4_9

 

 

Keylock

KEY4_10

 

 

Lamp

KEY4_11

 

 

Selectable QT KEY4_15

M destination only

 

Monitor A

KEY4_17

 

 

Monitor B

KEY4_18

 

 

Monitor C

KEY4_19

 

 

Monitor D

KEY4_20

 

 

RF Power Low KEY4_21

Default

 

Scan

KEY4_22

 

 

Scan DEL/ADD KEY4_23

 

 

Group Down KEY4_24

 

 

Group Up

KEY4_25

 

 

Scrambler

KEY4_26

Only when scrambler is set

7 [CH]

Channel Up/Down CH_UP/DN

Default

 

Group Up/Down GR_UP/DN

 

 

No Function KNOB_OFF

 

No.

Function

Choices

Display

Remarks

 

 

Optional Feature

 

8

Power On Tone

YES/NO

PONT_YES

Default:YES

 

 

 

 

 

9

Control Tone

YES/NO

CNTT_YES

Default:YES

 

 

 

 

 

10

Warning Tone

YES/NO

WART_YES

Default:YES

 

 

 

 

 

11

Time Out Timer

OFF,15-300/15s Step

TOT_60

Default:60s

 

 

 

 

 

12

TOT

OFF,1-10/

TOTP_PFF

Cannot be set when TOT is OFF.

 

Pre-Alert Time

1s Step

 

Default:OFF

 

 

 

 

 

13

TOT

OFF1-60/

TOTK_OFF

Cannot be set when TOT is OFF.

 

Rekey Time

1s Step

 

Default:OFF

 

 

 

 

 

14

TOT

OFF1-15/

TOTS_OFF

Cannot be set when TOT is OFF.

 

Reset Time

1s Step

 

Default:OFF

 

 

 

 

 

15

Clear to Transpond

YES

CTT_YES

 

 

 

 

 

 

 

(BCL for Transpond)

NO

CTT_NO

Default

 

 

 

 

 

16

Battery Save

ON

BATT_ON

Default

 

 

 

 

 

 

 

OFF

BATT_OFF

 

 

 

 

 

 

17

Signaling

OR

SIG__OR

Default

 

 

 

 

 

 

 

AND

SIG_AND

 

 

 

 

 

 

18

Squelch Level

0-9/1 Step

SQL__5

Default;5

 

 

 

 

 

19

Priority

None

PRI_NONE

Default

 

 

 

 

 

 

 

Fixed

PRI_FIX_

 

 

 

 

 

 

 

 

Selected

PRI_SEL_

 

 

 

 

 

 

20

Lock Back

0.5-5.0/0.05

LBA_500

Default:500ms Cannot be

 

Time A

 

 

set when Priority = none.

 

 

 

 

 

21

Lock Back

0.5-5.0/0.05

LBB_2000

Default:2000ms Cannot

 

Time B

 

 

be set when Priority = none.

 

 

 

 

 

22

Revert

Selected

REV_SEL

 

 

 

 

 

 

 

Channel

Last Called

REV_L/C_

Default

 

 

 

 

 

 

 

Last Used

REV_L/U_

 

 

 

 

 

 

 

 

Selected + Talk Back

REV_S/T_

 

 

 

 

 

 

 

 

Priority

REV_PRI_

 

 

 

 

 

 

 

 

Priority + Talk Back

REV_P/T_

 

 

 

 

 

 

23

Dropout

0-300/1s

DODT___3

Default;3s

 

Delay Time

 

 

 

 

 

 

 

 

24

Dwell Time

0-300/1s

DWL___3

Default;3s

 

 

 

 

 

 

 

 

DTMF

 

25

Digit Time

50-200/10ms

DIGT__50

Default;50ms

 

 

 

 

 

26

Inter Digit Time

50-1000/50ms

IDT___50

Default;50ms

 

 

 

 

 

27

First Digit Time

50-200/10ms

FDT___50

Default;50ms

 

 

 

 

 

28

First Digit Delay

50-1000/50ms

RIST_100

Default;100ms

 

 

 

 

 

29

Rise Time with QT

50-1000/50ms

RTWQ_100

Default;100ms

 

 

 

 

 

30

DIAL ID

Enable

DID_ENA

 

 

 

 

 

 

 

 

Diable

DID_DIS

Default

 

 

 

 

 

31

No.of

12Key

NODK_12

Default

 

 

 

 

 

 

DTMF Key

16Key

NODK_16

 

 

 

 

 

 

32

DTMF Hold Time

ON

DHT__ON

Default

 

 

 

 

 

 

 

OFF

DHT__OFF

 

 

 

 

 

 

33

Store and Send

ON

SAS__ENA

 

 

 

 

 

 

 

 

OFF

SAS__CSQ

Default

 

 

 

 

 

14

Page 14
Image 14
Kenwood TK-270G service manual TK-260G/270G, Realignment, No. Function