TK-260G/270G

ADJUSTMENT

Item

Condition

 

Measurement

Adjustment

Specifications/

 

Test equipment

 

Terminal

Parts

 

Method

Remark

 

 

 

 

 

 

 

 

 

 

1. Sensitivity

Adj item [SENS]

DVM

 

 

 

Encoder knob

 

fL : ([S.E N S]) : [88]

 

Adjustment

Adjust [∗∗∗]

 

 

 

 

 

 

 

fC : (S.E.N.S) : [134]

 

 

fL

fc

 

fH

 

 

 

 

fH : (S.E.N.S. .) : [180]

 

 

[S.E N S] [S.E.N.S] [S.E.N.S. .]

 

 

 

 

 

PTT : ON

 

 

 

 

 

 

 

 

 

 

 

2. BPF

(PANEL TEST MODE)

Tracking generator

 

ANT

L305, L306, L307

 

Adjust wave form

 

 

 

CH-Sig 2-1

 

spectrum analyzer

 

 

 

 

to figure 1.(fL)

 

 

 

Tra-G setting

-40dBm

 

 

 

BPF

 

 

 

 

 

 

CH-Sig 1-1

 

 

 

 

 

 

 

Check wave form to figure 2.(fC)

 

 

CH-Sig 3-1

 

 

 

 

 

 

 

Check wave form to figure 1.(fH)

 

 

 

 

fL

fH

 

 

fC

 

 

 

 

 

 

 

 

Fig. 1

 

Fig. 2

 

 

 

 

 

 

 

BPF-WAVE

 

 

 

 

 

 

 

 

 

 

 

 

3. Sensitivity

[Panel Test Mode]

SSG

ANT

 

 

 

 

 

Check

1)

CH-Sig:1-1

AF VTVM

 

 

Check

12dB SINAD or

 

 

 

 

SSG OUT

Oscilloscope

 

 

 

more

 

 

 

 

Wide:-117dBm (0.3V)

 

 

 

 

 

 

 

 

 

(MOD:1kHz / ±3kHz)

 

 

 

 

 

 

 

 

 

Narrow:-117dBm (0.3V)

 

 

 

 

 

 

 

 

 

(MOD:1kHz / ±1.5kHz)

 

 

 

 

 

 

 

4. Squelch (open)

1)

Adj item [SQL3]

 

 

 

Encoder

Adjust to the

 

 

Adjust

 

Adjust [∗∗∗]

 

 

 

knob

squelch

 

 

(Wide)

 

SSG OUT:

 

 

 

squelch.

threshold point

 

 

 

 

-124dBm (0.14V)

 

 

 

 

 

 

 

 

2)

Adj item [SQL3.]

 

 

 

 

 

 

 

(Narrow)

 

Adjust [∗∗∗]

 

 

 

 

 

 

 

 

 

-124dBm (0.14V)

 

 

 

 

 

 

 

5. Squelch(Tight)

1)

Adj item [SQL9]

 

 

 

 

Adjust to the

 

 

Adjust

 

Adjust [∗∗∗]

 

 

 

 

squelch

 

 

[Wide]

 

SSG OUT:-117dBm (0.3V)

 

 

 

 

threshold point

 

 

 

 

 

 

 

 

 

 

 

 

[Narrow]

1)

Adj item [SQL9.]

 

 

 

 

 

 

 

 

 

SSG OUT:-117dBm (0.3V)

 

 

 

 

 

 

 

6. Squelch

[Panel Test Mode]

 

 

 

Check

Squelch must

 

 

Check

1)

CH-Sig:1-1

 

 

 

 

be opened.

 

 

 

 

SQ Level:[SQL5]

 

 

 

 

 

 

 

 

 

SSG OUT:

 

 

 

 

 

 

 

 

 

-118dBm (0.28V)

 

 

 

 

 

 

 

 

2)

SSG OUT:OFF

 

 

 

 

Squelch must

 

 

 

 

 

 

 

 

 

be closed.

 

 

 

 

 

 

 

 

 

 

 