TK-260G/270G

ADJUSTMENT

Adjustment points TX-RX unit (X57-587) Component side view

ANT

LV

VR1

C13 CN3

IC12

MIC IC14

BPF

MIC SP

Foil Side View

 

MIC

SP

BPF

 

 

 

 

L307

Battery terminal

L305

L306

 

TC1

ANT

CV TC2

VR1 : Frequency adjustment

TC1 : Transmit lock voltage adjustment

 

TC2 : Receive lock voltage adjustment

 

L305:

} Band-pass filter waveform adjustment

 

L307:L306:

BPF : Band-pass filter test point

CV(LV) : Lock voltage adjustment terminal.

Fig. 2 Adjustment points

40

Page 40
Image 40
Kenwood TK-270G, TK-260G service manual Adjustment points TX-RX unit X57-587 Component side view, Foil Side View