The problems described in this table are commonly encountered operational malfunctions. These types of difficulties are usually caused by improper hook-up, accidental incorrect control settings, or operator error due to incomplete programming. These problems are usually not caused by circuit failure. Please review this table, and the appropriate section(s) of this instruction manual, before assuming your transceiver is defective.

Note: Placing a powered portable transceiver near this transceiver may cause noise in the transceiver.

Problem

 

Probable Cause

 

Corrective Action

Page

 

 

Ref.

 

 

 

 

 

 

 

The transceiver will not

1

DC power supply is OFF.

1

Switch ON the DC power supply.

18

power up after

2

Faulty power cable

2

Inspect the power cable. Confirm

2, 3

connecting a 13.8 V DC

 

 

 

polarities are correct.

 

power supply and

 

 

 

Red: positive (+); Black: negative (–)

 

pressing [

 

]. Nothing

3

The power cable is not connected

3

Confirm the connections to the DC

2, 3

 

 

appears on the display,

 

securely.

 

power supply are secure.

 

and no receiver noise is

4

Power cable fuse is open.

4

Look for the cause of the blown fuse.

5

heard.

 

 

 

After inspecting and correcting any

 

 

 

 

 

 

 

problems, install a new fuse of the

 

 

 

 

 

 

 

specified rating.

 

 

 

 

 

 

 

 

 

After switching ON the

1

The input voltage is outside 13.8 V

1

Correct the input voltage or use a 12 to

2, 3

power, the transceiver

 

DC ±15% (11.7 to 15.8 V DC).

 

16 V battery.

 

does not function

2

The microprocessor has

2

Review “MICROPROCESSOR

88

normally. For example,

 

malfunctioned.

 

RESET”. After understanding what

 

no digits or incorrect

 

 

 

data will be lost, do a Partial Reset. If

 

digits appear on the

 

 

 

the problem remains, do a Full Reset.

 

display.

 

 

 

 

 

 

 

 

 

 

 

 

 

After switching ON the

1

The current rating of the DC

1

Use the DC power supply that has

3

transceiver, the

 

power supply is too low.

 

20.5 A or more current rating.

 

transceiver refuses to

2

Two same DC power supplies

2

Connect 2 DC power supplies to the

3

transmit.

 

(20.5 A or more each) or a DC

 

TS-480HX transceiver. The voltage

 

 

 

 

 

power supply that has 41 A more

 

difference between 2 DC power

 

 

 

 

 

current capacity.

 

supplies must be within 1.0 V to

 

 

 

 

 

 

 

transmit. Also, confirm each DC power

 

 

 

 

 

 

 

supply has a 20.5 A or higher current

 

 

 

 

 

 

 

rating. If a DC power supply that has

 

 

 

 

 

 

 

41 A more current capacity, two same

 

 

 

 

 

 

 

type of DC cables must be used.

 

 

 

 

 

 

 

 

 

The transceiver does

1

Procedures are not being

1

Review “WRITING CONVENTIONS

ii

not respond correctly

 

followed precisely.

 

FOLLOWED”.

 

after pressing key

2

The Frequency Lock function is

2

Press [MENU/ F.LOCK] (1 s) to switch

63

combinations or turning

 

ON.

 

the function OFF.

 

controls per instructions

3

The microprocessor and its

3

Review “MICROPROCESSOR

88

in this manual.

 

memory need resetting.

 

RESET”. After understanding what

 

 

 

 

 

 

 

data will be lost, do a Partial Reset. If

 

 

 

 

 

 

 

the problem remains, do a Full Reset.

 

 

 

 

 

 

 

The frequency cannot

The Frequency Lock function or

Press [MENU/ F.LOCK] (1 s) to turn the

63

be changed.

Lock All function is ON.

Frequency Lock function OFF. The “ ”

 

 

 

 

 

 

icon disappears.

 

 

 

 

 

 

 

 

 

SSB audio quality is

1

The wrong operation mode is

1

Select USB or LSB for the mode.

19

very poor; the high or

 

selected for the receiver.

 

 

 

low audio frequencies

2

The AF DSP filter is incorrectly

2

Press [FIL/ NAR] then turn the MULTI

46

are absent.

 

set.

 

control to adjust the DSP filter width.

 

 

 

 

3

Noise Reduction 1 or 2 is ON.

3

Press [NR] until the NR function turns

47

 

 

 

 

 

 

OFF.

 

 

 

 

4

Beat Cancel 1 or 2 is ON.

4

Press [BC/ CW.T] until the BC function

47

 

 

 

 

 

 

turns OFF.

 

 

 

 

 

 

 

 

 