Kenwood XD-9581MD MD recorder section other symptoms, Symptoms related to MD standard

Models: XD-9581MD

1 84
Download 84 pages 9.74 Kb
Page 80
Image 80
Symptoms related to MD standard

80

Preparation section

Basic section

Application section

Knowledge sections

 

 

 

 

 

In case of difficulty

 

 

 

 

 

XD-9581MD (En)

Symptoms related to MD standard

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

 

 

Cause

 

 

 

 

 

“DISC FULL” is displayed while the disc still has a remaining re-

ÖMore than 255 tracks (track No. 256 or more) cannot be recorded. (There

cordable time.

 

may be also cases in which recording is impossible while the track

 

 

 

number is less than 256.)

 

 

 

 

In such a case, the REMAIN time display shows “0:00”.

 

 

 

 

 

The possible recording time does not increase even when a short

ÖWhen the remaining time of the entire disc is less than 12 sec, the

track is erased.

 

remaining time indication on the display becomes “0:00”. When the

 

 

 

total time of the deleted tracks exceeds 12 sec, the display changes to

 

 

 

the recordable time.

 

 

 

 

 

ÖWhen a short track is deleted on a repeatedly edited disc, the remaining

 

 

 

time may not increase.

 

 

 

 

 

 

 

Tracks can not be connected.

 

ÖConnection of the track resulting from edit processing may not be

 

 

 

possible.

 

 

 

 

 

 

The time which has been recorded on the MD and the remaining

ÖAs recording is executed with 2 sec. as the minimum unit, the display

time do not add up to the maximum recording time (60 or 74 min.).

time may not coincide.

 

 

 

 

 

 

When search is performed in a track which has been compiled by

ÖThis derives from the restriction in the MD system standard and not a

editing, the sound is sometimes interrupted.

 

malfunction.

 

 

 

 

 

 

The track numbers are not assigned correctly.

ÖDepending on the contents of the recorded source (CD etc.), the track

 

 

 

numbers may not be assigned correctly.

 

 

 

 

ÖThe track number may be increased in case of dirt or scratches on the CD.

 

 

 

 

“DISC READING” is displayed for an abnormally long time.

ÖWhen a new recordable MD (with nothing recorded) is inserted,

 

 

 

“DISC READING” is displayed longer than usual.

 

 

 

 

 

The time display becomes inaccurate with a monaurally recorded

ÖMonaural recording and stereo recording are executed according to

disc.

 

different formats. This is not a malfunction.

 

 

 

 

 

 

Input of 1792 title characters is not possible.

 

ÖThe title recording area is used in units of 7 characters, so that input of

 

 

 

1792 characters may not be possible.

 

 

 

 

 

 

 

MD recorder section (other symptoms)

 

 

 

 

 

 

 

 

 

 

Symptom

 

Cause

 

Remedy

 

 

 

 

 

 

 

Sound is not output even when the play key

 

ÖThe cords are connected erroneously.

 

ÖConnect the cords in accordance with

6

is pressed.

 

 

 

 

“System connections”.

 

 

ÖNo disc has been loaded.

 

ÖLoad a disc.

ª

 

 

ÖA non-recorded disc has been loaded.

 

ÖLoad a prerecorded disc or playback-

j

 

 

 

 

 

only disc.

 

 

 

 

 

 

Recording is not possible

 

ÖThe disc is write-protected.

 

ÖChange the position of the write pro-

 

 

 

 

 

 

tect tab to the write position or use a

5

 

 

 

 

 

recordable disc.

 

 

ÖAn attempt is made to record digital signal from

 

ÖRecording is not possible.

k

 

 

a source while its digital copy has been prohib-

 

 

 

 

 

ited by SCMS.

 

 

 

ö

 

 

ÖThe recording level is too low. (with use of AUX

 

ÖAdjust the input level.

 

 

or TAPE)

 

 

 

j

 

 

ÖA playback-only disc has been loaded.

 

ÖUse a recordable disc.

 

 

ÖThe disc does not have a recordable area.

 

ÖUse another disc.

°

 

 

ÖThe input selector is set to MD.

 

ÖSet the input selector to the source to

¥

 

 

 

 

 

be recorded.

 

 

 

 

 

 

Sound is distorted.

 

ÖThe recording level has not been adjusted(with

 

ÖAdjust the input level.

ö

 

 

use of AUX or TAPE).

 

 

 

¥

 

 

ÖA disc in which distorted sound has been re-

 

ÖRecord again.

 

 

corded is played.

 

 

 

 

 

 

 

 

 

 

Noise is noticeable.

 

ÖAn external noise is induced.

 

ÖInstall the unit at a position apart from

 

 

 

 

 

 

an electric appliance or TV set.

 

 

 

 

 

 

 

The recorded volume changes during the

 

ÖThe jog dial has been moved during analog

 

ÖDo not move the knobs during record-

¥

recording.

 

recording.

 

 

ing.

 

 

 

 

 

 

The display goes out for a moment after the

 

ÖSwitching is operated too quickly.

 

ÖThis is not a malfunction.

 

unit has been turned ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 80
Image 80
Kenwood XD-9581MD instruction manual MD recorder section other symptoms, Symptoms related to MD standard