Service Manual
b)Go to next slide position
Start
Slide LIFTER Up
Next Slide
SM
Projector Status: | There is a slide in the gate and it is projected. |
Start action: | The forward or reverse BUTTON is actuated |
| or next slide is selected with RANDOM |
| ACCESS. |
See Slide Change Sequence, page
Position
?
reverse
RANDOM ACCESS: The MICROCONTROLLER selects shortest distance to the next slide.
forwards
Tray Motor forward | Tray Motor reverse |
More than | Yes | |||||
4 Step Signals | ||||||
|
|
|
| |||
missed |
|
|
|
| ||
? | No |
|
|
|
| |
|
|
| Transport Failure | |||
|
|
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
| Power LED Blinking | ||
|
|
|
|
|
| |
|
|
|
|
|
| |
No requested |
| No | ||||
Position |
| |||||
|
|
|
| |||
reached |
|
|
|
| ||
? |
|
|
|
|
| |
| Yes |
|
|
|
| |
Set Tray Position |
|
| Write failure | |||
to next slide position |
| into Memory | ||||
|
|
|
| |||
|
|
|
|
| ||
Slide LIFTER down |
|
| Projector | |||
Slide projected |
|
| inoperable |
END
figure
The MICROCONTROLLER energizes the TRAY MOTOR for 47 steps (80 tray) or 27 (140 tray) for each slide.
The MICROCONTROLLER checks feedback from tray MOTION CONTROL CIRCUIT.
If more than 4 feedback pulses are missed, exit to the failure routine.
For RANDOM ACCESS: The TRAY MOTOR ON until the position is reached.
For FORWARD/REVERSE BUTTONS:
-tray moves only for one slide
-slide is projected
-if transport button is still pressed,
a slide is lifted up and the tray moves until button is released but stops at the ZERO POSITION.
The MICROCONTROLLER sets the next position into memory.
The SLIDE LIFTER Down procedure starts.
For details, see Slide Change Sequence.
03/98 | Kodak AG, Stuttgart |