Service Manual

SM2547-1

MECHANISM FRAME and LENS MOUNT

1. Remove the UPPER HOUSING. See page 4-1.

2. Remove the CENTER HOUSING. See page 4-4.

3. Remove the 4 SCREWS and the TRANSFORMER. See page 4-11.

4. Remove the SCREW and disconnect the NEUTRAL WIRE.

5. For Model 5020, 9020 and 9020/CINE remove the SCREW, the AF PCB and the 2 CONNECTORS from the AF PCB.

6. Lift the MECHANISM FRAME and LENS MOUNT and remove the 3 CONNECTORS J 3, J 10, J 12. See page 4-19.

SCREW (4)

SCREW

AF PCB

TRANSFORMER

LENS MOUNT

NEUTRAL WIRE

MECHANISM

FRAME

figure 4-17

03/98

4-12

Kodak AG, Stuttgart