FUNCTION CODES

USING FUNCTION CODES

There are a variety of functions available which may be

 

used to temporarily change operating conditions and

 

values, and to obtain system and accessory status

 

information.

To execute a function code:

Press the F key.

Press the numeric keys which correspond to the desired function code.

Press the Enter key.

Additional input may be necessary:

If the function is used to enable/disable an option (turn an option on or off):

Press the number one (1) key to turn the option ON; or

Press the number zero (0) key to turn the option OFF.

Press the Enter key.

If the function requires numeric input:

Press the number key(s) required.

Press the Enter key.

If the function is used to increment/decrement a measurement:

Press the up arrow key to increment the measurement by one (1) inch (25 mm); or

Press the down arrow key to decrement the measurement by one (1) inch (25 mm);

or

Press the right arrow key to increment the measurement by one-eighth (1/8) inch (3 mm); or

Press the left arrow key to decrement the measurement by one-eighth (1/8) inch (3 mm).

Press the Enter key.

To cancel a function or clear the Status Display after executing a function, press the Clear/Cancel key.

A-61003 September 1993