INSTALLATION

SOLVENT WELD TUBING

Solvent weld the PVC tubing connections￿ using care to maintain the established drainage pitch in the lines￿ Make sure each union connection includes the required O6ring￿ Securely hand tighten the union nuts￿

Check Point #5

-Confirm that all previous check point requirements have been met.

-Solvent weld all pvc tubing joints, and hand tighten the union nuts with the O1rings in place.

MAKE ELECTRICAL CONNECTIONS

WARNING: Risk of electrical shockTo .

reduce the risk of electric shock￿ connect only to a properly grounded￿ grounding6type receptacle￿ protected by a Ground6Fault Circuit6Interrupter ￿GFCI￿￿ Do not remove the plug￿s grounding pin￿ Do not use a grounding adapter￿

The Kohler Custom BodySpa is equipped with a cord and plug￿ All wiring of the pump has been completed at the factory￿ A licensed electrician must install a GFCI6protected￿ 120 V￿ 20 A￿ grounded outlet￿ Locate the outlet behind the BodySpa￿ and within 246inches of the pump￿ Plug the BodySpa into this outlet￿ No other load should be on this circuit￿

11￿347626AA ￿A￿

1￿

Kohler Co￿￿ Kohler￿ WI