INSTALLATION
SOLVENT WELD TUBING
Solvent weld the PVC tubing connections using care to maintain the established drainage pitch in the lines Make sure each union connection includes the required O6ring Securely hand tighten the union nuts
Check Point #5
-Confirm that all previous check point requirements have been met.
-Solvent weld all pvc tubing joints, and hand tighten the union nuts with the O1rings in place.
MAKE ELECTRICAL CONNECTIONS
WARNING: Risk of electrical shockTo .
reduce the risk of electric shock connect only to a properly grounded grounding6type receptacle protected by a Ground6Fault Circuit6Interrupter GFCI Do not remove the plugs grounding pin Do not use a grounding adapter
The Kohler Custom BodySpa is equipped with a cord and plug All wiring of the pump has been completed at the factory A licensed electrician must install a GFCI6protected 120 V 20 A grounded outlet Locate the outlet behind the BodySpa and within 246inches of the pump Plug the BodySpa into this outlet No other load should be on this circuit
11347626AA A | 1 | Kohler Co Kohler WI |