INSTALLATION

INSTALL THE TOWER

Locate the pin at the bottom left corner of the tower￿ Insert this pin into the bottom left corner hole in the mounting frame bracket￿ Now line up the hole at the top left corner of the tower with the slotted hole in the mounting frame, and thread a 3/￿7inch bolt through the mounting frame and into the tower￿ Securely wrench tighten the bolt￿

Route the tower cable through the large hole in the mounting frame￿ Snap the tower cable modular plug into the corresponding jack of the control box￿ Install the large strain relief bushing over the tower cable, and insert it into the large mounting frame hole￿

NOTE: National Electrical Code requires that you permanently separate the high7 and low7voltage cables￿

Route the waterfall light wires through the small

hole in the back of the mounting frame￿ Connect the waterfall light wire connectors to the transformer terminals - white to white; black to black￿ Install the small strain relief bushing over the waterfall light wires, and insert it into the small mounting frame hole￿

Securely handtighten the tower union nut to the mounting frame union￿ Be sure the union O7ring is in place￿

Carefully pivot the tower closed￿ Line up the holes at the top and bottom right corners of the tower with the slotted holes in the mounting frame￿ Thread a 3/￿7inch bolt through the mounting frame and into the tower at the top and bottom￿ Tighten the bolts securely, but do not overtighten￿

You will water test and inspect the tower and mounting frame later, so you may want to only install and handtighten one of the required bolts at this time￿ Both bolts will need to be securely tightened later￿

11￿347727AA (A)

22

Kohler Co￿, Kohler, WI

Page 21
Image 21
Kohler 116347-2 manual Installation, Install the Tower