5: Configuration Using Web Manager

 

Endpoint Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

Endpoint Configuration

 

Description

 

 

 

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

Local Port

 

Enter the local port number.

 

 

 

 

 

 

 

 

 

 

Auto increment for active

 

Select to auto-increment the local port number for new outgoing

 

 

 

connect

 

connections. The range of auto-incremented port numbers is

 

 

 

 

 

 

50,000 to 59,999 and loops back to the beginning when the

 

 

 

 

 

 

maximum range is reached.

 

 

 

 

 

 

 

 

 

 

Remote Port

 

Enter the remote port number.

 

 

 

 

 

 

 

 

 

 

Remote Host

 

Enter the IP address of the remote device.

 

 

 

 

 

 

 

 

 

Common Options

 

 

 

 

 

 

 

 

 

 

 

 

 

Common Option Settings

 

Description

 

 

 

 

 

 

 

 

 

 

Telnet Com Port Cntrl

 

This field is available for configuration only when Active Connect

 

 

 

 

 

 

is set to None. Select Enable to permit Telnet communication to

 

 

 

 

 

 

the unit. The Telnet Com Port Cntrl feature is used in

 

 

 

 

 

 

conjunction with the Com Port Redirector (CPR) utility. (See the

 

 

 

 

 

 

CPR Online Help for details.)

 

 

 

Terminal Name

 

This field is available for configuration only when Telnet Mode is

 

 

 

 

 

 

set to Enable.

 

 

 

 

 

 

Use the terminal name for the Telnet terminal type. Enter only

 

 

 

 

 

 

one name. When this option is enabled, the unit also reacts to the

 

 

 

 

 

 

end of record (EOR) and binary options, which can be used for

 

 

 

 

 

 

applications such as terminal emulation to IBM hosts.

 

 

 

 

 

 

 

 

 

 

Connect Response

 

A single character is transmitted to the serial port when there is a

 

 

 

 

 

 

change in connection state. Default setting is None.

 

 

 

Use Hostlist

 

If this option is set to True, the device server scrolls through the

 

 

 

 

 

 

host list until it connects to a device listed in the host list table.

 

 

 

 

 

 

Once it connects, the unit stops trying to connect to any others. If

 

 

 

 

 

 

this connection fails, the unit continues to scroll through the table

 

 

 

 

 

 

until it connects to another IP in the host list.

 

 

 

 

 

 

The host list is disabled for Manual Mode and for Modem Mode.

 

 

 

 

 

 

The unit will not accept a data connection from a remote device

 

 

 

 

 

 

when the host list option is enabled.

 

 

 

 

 

 

 

 

 

 

LED

 

Select Blink for the status LEDs to blink upon connection or

 

 

 

 

 

 

None for no LED output.

 

Disconnect Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect Mode Settings

 

 

Description

 

 

 

 

 

 

 

 

 

On Mdm_Ctrl_In Drop

 

Set to Yes for the network connection to or from the serial port to

 

 

 

 

 

 

disconnect (drop) when Modem Control In transitions from an

 

 

 

 

 

 

asserted state to not asserted state. The default setting is No.

 

 

 

Hard Disconnect

 

When set to Yes, the TCP connection closes even if the remote

 

 

 

 

 

 

site does not acknowledge the disconnect request.

 

Micro125 User Guide

31

Page 31
Image 31
Lantronix 900-588 manual Endpoint Configuration Description Settings, Common Option Settings Description