6: Configuration via Telnet or Serial Port (Setup Mode)

To establish a Telnet connection:

1.From the Windows Start menu, click Run and type the following command, where x.x.x.x is the IP address, and 9999 is the unit’s fixed network configuration port number:

Windows: telnet x.x.x.x 9999

UNIX: telnet x.x.x.x:9999

2. Click OK. The following information displays.

Figure 6-1. MAC Address

MAC address 00204AAE0412

Software version V6.8.0.4 (121207) M125

AES library version 1.8.2.1

Press Enter for Setup Mode

3.To enter Setup Mode, press Enter within 5 seconds. The configuration settings display, followed by the Change Setup menu.

Figure 6-2. Setup Menu Options

Change Setup:

 

0

Server

 

1

Channel 1

 

2

Channel 2

 

5

Expert

 

6

Security

 

7

Defaults

 

8

Exit without save

Your choice?

9

Save and exit

4.Select an option on the menu by entering the number of the option in the Your choice ? field and pressing Enter.

5.To enter a value for a parameter, type the value and press Enter, or to confirm a current value, just press Enter.

6.When you are finished, save the new configuration (option 9). The unit reboots.

Serial Port Connection

To configure the unit through a serial connection:

1.Connect a console terminal or PC running a terminal emulation program to your unit's serial port.

2.Set the terminal emulator serial port settings to 9600 baud, 8 bits, no parity, 1 stop bit, no flow control.

Note: The Micro125 always uses these serial port settings on boot-up.

3.Reset the Micro125 unit by cycling the unit's power (turning the power off and back on). Immediately upon resetting the device, enter three lowercase x characters (xxx).

Micro125 User Guide

36

Page 36
Image 36
Lantronix 900-588 Serial Port Connection, To establish a Telnet connection, Click OK. The following information displays