8: Setup Mode: Channel Configuration

Figure 8-2. Hostlist Option

Baudrate (9600) ?

I/F Mode (4C) ?

Flow (00) ?

Port No (10001) ?

ConnectMode (25) ?

Send '+++' in Modem Mode (Y) ?

Auto increment source port (N) ?

Hostlist :

Port : 00023

01. IP : 172.019.000.001

02. IP : 172.019.000.002

Port :

03001

03. IP : 172.019.000.003

Port :

10001

Change Hostlist ? (N) ? Y

 

.(000)

.(001)

Port : (23) ?

01. IP address : (172) .(019)

02. IP address : (172) .(019)

.(000)

.(002)

Port : (3001) ?

03. IP address : (172) .(019)

.(000)

.(003)

Port : (10001) ?

04. IP address : (000) .(000)

.(000)

.(000)

 

Hostlist :

 

 

Port : 00023

 

01. IP : 172.019.000.001

 

02. IP : 172.019.000.002

Port : 03001

 

03. IP : 172.019.000.003

Port : 10001

 

DisConnMode

(00)

?

 

 

 

 

FlushMode

(00)

?

 

 

 

 

DisConnTime

(00:00) ?:

 

 

 

 

SendChar 1

(00)

?

 

 

 

 

SendChar 2

(00)

?

 

 

 

 

To enable the hostlist:

1.Enter a Connect Mode of 0x20 (2X), where X is any digit. The menu shows you a list of current entries already defined in the product.

2.To delete, modify, or add an entry, select Yes. If you enter an IP address of 0.0.0.0, that entry and all others after it are deleted.

3.After completing the hostlist, repeat the previous step if necessary to edit the hostlist again.

4.For Retrycounter, enter the number of times the Lantronix unit should try to make a good network connection to a hostlist entry that it has successfully ARPed. The range is 1-15, with the default set to 3.

5.For Retrytimeout, enter the number of seconds the unit should wait before failing an attempted connection. The time is stored as units of milliseconds in the range of 10- 65535. The default is 250.

Micro125 User Guide

47

Page 47
Image 47