Paradyne 9128-II, CSU, DSU, 9126-II manual Service Level Verification Performance Statistics

Models: CSU, DSU 9126 9126-II 9128-II

1 470
Download 470 pages 16.65 Kb
Page 234
Image 234

7. Operation and Maintenance

Service Level Verification Performance Statistics

These statistics appear when Service Level Verification (SLV) is selected from the Performance Statistics menu.

Main Menu Status Performance StatisticsService Level Verification

They only appear for the network interface and only if DLCIs are multiplexed or IP Enabled.

Information displayed on the SLV Performance Statistics screen depends on DLCI type. See Table 7-16, SLV Performance Statistics for Multiplexed DLCI or

Table 7-17, SLV Performance Statistics for IP Enabled DLCI.

On either screen, select PrevDLCI or NextDLCI to view statistics for the previous or next DLCI on the link. On the IP Enabled DLCI screen, select PrevPath or NextPath to view statistics for the previous or next path associated with the DLCI.

For standard or multiplexed DLCIs, the statistics collected by the unit depend upon the device at the far end of the connection. If the far-end device is a FrameSaver SLV unit, frame relay, latency, and FDR/DDR performance statistics are collected. The Frame Relay Delivery Ratio is the number of delivered frames/offered frames; the Data Delivery Ratio is the number of delivered octets/offered octets.

If the far-end device is a non-FrameSaver device, or a FrameSaver 9120 or 9620, only frame relay statistics are collected.

Table 7-16. SLV Performance Statistics for Multiplexed DLCI (1 of 3)

Statistic

What It Indicates

 

 

Far End Circuit

Number of the multiplexed DLCI or VPI/VCI (Virtual Path

 

Identifier/Virtual Channel Identifier) at the other end of the

 

connection.

 

If the far-end circuit is a DLCI, the DLCI number (16–1007)

 

appears. If a VPI/VCI, the number is displayed as xx,yyy, xx

 

being the VPI number (0 –15) and yyy being the VCI number

 

(32–2047).

 

None appears if the unit has not communicated with the other

 

end.

 

 

Far End IP Addr

IP Address of the device at the other end of the multiplexed

 

DLCI connection.

 

None appears if the FrameSaver unit has not communicated

 

with the other end, or if the device at the other end of the

 

multiplexed DLCI does not have an IP Address configured.

 

 

Dropped SLV

The number of SLV inband sample messages sent for which a

Responses

response from the far-end device has not been received.

 

 

*Only appears for FrameSaver units when the SLV Delivery Ratio option is enabled.

7-52

September 2002

9128-A2-GB20-80

Page 234
Image 234
Paradyne 9128-II Service Level Verification Performance Statistics, 17, SLV Performance Statistics for IP Enabled Dlci