Paradyne 9128-II, CSU, DSU, 9126-II manual Rmon Alarm and Event Defaults, Dial Control Extension MIB

Models: CSU, DSU 9126 9126-II 9128-II

1 470
Download 470 pages 16.65 Kb
Page 366
Image 366

B. SNMP MIBs and Traps, and RMON Alarm Defaults

Table B-9. dialControl Traps (2 of 2)

Trap

Variable-Bindings

Possible Cause

 

 

 

Dial Control Extension MIB

 

 

 

 

dialCtlPeerCall-

callHistoryPeerId

A peer-to-peer call was not

Rejected

(RFC 2128)

successful; the call was rejected

 

callHistoryPeerIfIndex

by the far end.

 

 

 

(RFC 2128)

ISDN Call Profile has been

 

callHistoryLogicalIfIndex

Tdisabled.

 

(RFC 2128)

This unit’s phone number was

 

callHistoryPeerAddress

not in the far end device’s ISDN

 

Call Profile.

 

T(RFC 2128)

 

devLastTrapString

String:

 

‘Call on $ifString using B-Chnl

 

(devHealthAndStatus.-

 

$channel rejected by remote.’

 

mib)

 

 

 

 

 

RMON Alarm and Event Defaults

The FrameSaver unit supports automatic generation of RMON alarm and event information. Each alarm sets an SNMP variable to monitor. When the threshold set for the monitored variable is exceeded, an SNMP trap or a log event is sent.

Event Defaults

Since all events sent are under the control of the FrameSaver unit, there is no need to define multiple events for each alarm type, so only the following two events need to be generated:

eventIndex

eventDescription

eventType

eventCommunity

 

 

 

 

65533

Default SLV Rising Event

log-and-trap(4)

0

 

 

 

 

65534

Default SLV Falling Event

log-and-trap(4)

0

 

 

 

 

he alarm default tables starting on the next page show how each RMON default alarm is set by the FrameSaver unit, shows the alarm and event types, the interval used when generating alarms, and thresholds.

Physical Interface Alarm Defaults

Frame Relay Link Alarm Defaults

TDLCI Alarm Defaults – Paradyne Area DLCI Alarm Defaults – NetScout Area

See Standards Compliance for SNMP Traps on page B-8for information about how traps work, and Traps: RMON-Specificon page B-16for traps specific to remote monitoring.

B-18

September 2002

9128-A2-GB20-80

Page 366
Image 366
Paradyne 9128-II, CSU, DSU, 9126-II Rmon Alarm and Event Defaults, EventIndex EventDescription EventType EventCommunity