Paradyne 9126, CSU, DSU Placing a Test Call Nondisruptive, Main Menu→ Test→ Isdn Call/PVC Tests

Models: CSU, DSU 9126 9126-II 9128-II

1 470
Download 470 pages 16.65 Kb
Page 255
Image 255

7. Operation and Maintenance

Placing a Test Call (Nondisruptive)

Use this procedure to test the ISDN path to each remote site. This procedure will not put the system into backup.

Procedure

1.Make sure the ISDN Link Profiles and DLCIs are set up correctly for the DBMs at each end (see Modifying ISDN Link Profiles in Chapter 4, Configuration Options.

Main Menu Configuration ISDN Link Profiles Main Menu Configuration ISDN DLCI Records

2.Place a Test Call from one of the devices.

Main MenuTestISDN Call/PVC Tests

Select the link to be tested.

Start a Test Call. The Status should be Active.

If the Result is . . .

Then . . .

 

 

Frame Relay Link Up

The call was successful.

 

 

Frame Relay Link Down

The call was not successful. Verify the configuration and

 

Link Status in the ISDN Link Profile.

 

 

Select Stop to end the Test Call.

Use this procedure to test the ISDN path to each remote site. This procedure will not put the unit into backup.

9128-A2-GB20-80

September 2002

7-73