7. Operation and Maintenance
7-16 September 2002 9128-A2-GB20-80
Please Wait Command takes longer
than 5seconds. Wait until message clears.
Port Inactive

(FrameSaver SLV

9128-II only)

The port is disabled, or it
supports synchronous data
when a DTE Loopback was
started.
No action is needed.
Resetting Device,
Please Wait ... Yes (or y) was entered in
the

Reset COM Port usage

field of the System Paused
menu.
No action needed.
Save Cancelled

(FrameSaver SLV

9128-II only)

Changes were made on the
Easy Install screen, but
when it came to saving the
changes, the Esc key was
pressed or No was entered
in response to the Save
Changes? prompt.
No action is needed.
Test Active No higher priority System
and Test Status messages
exist, and a test is running.
Contact service provider if test
initiated by the network.
Wait until the test ends and
message clears.
Cancel all tests from the Test
screen (Path: main/test).
Stop the test from the same
screen the test was started
from.
User Interface Already
in Use Two Telnet sessions are
already in use when an
attempt to access th e
menu-driven user interface
through the COM port is
made.
IP addresses and logins of
the users currently
accessing the interface are
also provided.
Wait and try again.
Contact one of the IP address
user and request that they log
off.
User Interface Idle Previously active session is
now closed/ended, and
access via the COM port is
now available.
Log on to the FrameSaver unit.
Session has been ended
due to timeout. No action needed.

Table 7-6. Device Messages (5 of 6)

Message What It Indicates What To Do