4. Configuration Options

For easy movement between screens, select the FrAssign function key to go directly to the Frame Relay Network Assignments screen or the DSXAssign function key to go to the DSX-1 to Network Assignments screen.

ime Slot Assignment Rules:

To assign a synchronous data port to network or DSX-1 time slots, Port-2’s

Port Use option must be set for Synchronous Data (see Table 4-7, Data Port

TPhysical Interface Options).

If the DSX-1 interface is disabled, only Net1 is available for synchronous data port assignment (see the Interface Status option in Table 4-8,DSX-1 Physical Interface Options).

Procedure

1. Select one of the following menu selection sequences:

Main Menu Configuration Time Slot Assignment

Sync Data Port Assignments or

Main Menu Easy InstallTime Slot Assignment Screen

2.Select an interface in the Assign To field. A matrix of the current cross-connect status of all time slots on the selected interface appears.

3.Move the cursor to the next time slot that can be edited (underlined). Use the spacebar or type in the desired time slot to display its time slot assignment.

4.Repeat Step 3 until the synchronous data port is assigned to all desired time slots.

5.Save the configuration.

Clearing Assignments

Clearing assignments sets all time slots to Unassgn (unassigned).

Main Menu Configuration Time Slot AssignmentClear Assignments