4. Configuration Options

Table 4-15. PVC Connection Options (2 of 4)

Source EDLCI

Possible Settings: 0 – 62

Default Setting: Initially blank; no default.

Specifies the source Embedded Data Link Connection Identifier (EDLCI) for a frame relay interface when a multiplexed DLCI record is selected as one end of a connection.

Display Conditions – This option only appears when Source DLCI contains a multiplexed DLCI record number.

0 – 62 – Specifies the EDLCI number.

Primary Destination Link

Possible Settings: Net1-FR1,ISDN Link Name, Rtr-S0

Default Setting: Initially blank; no default.

Specifies the frame relay interface used as the primary destination link; the to end of a from-to link. The only valid settings for this configuration option are frame relay interfaces that have at least one DLCI or EDLCI defined which are not part of a PVC connection or management link. For example, if the network interface has no DLCIs defined, Net1-FR1 would not appear as a valid setting.

Net1-FR1– Specifies the Network interface as the destination link.

ISDN Link Name – For units with ISDN backup capability, specifies the ISDN link of the DBM as the destination of the connection. This can be any nonnull link name configured on an ISDN frame relay link.

Rtr-S0– For the FrameSaver SLV 9126-II Router, specifies the virtual router port as the destination link.

Primary Destination DLCI

Possible Settings: 16 – 1007

Default Setting: Initially blank; no default.

Specifies the primary destination DLCI for a frame relay interface. The DLCI must be defined and cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least one EDLCI must be unconnected for the DLCI to be a valid selection.

NOTES:

Primary Destination DLCI has no value if Primary Destination Link contains no value.

When an ISDN DBM is installed and the DLCI assigned to the PVC is in a Backup Group (see Table 4-14, DLCI Record Options), the letter designation assigned to the group of DLCIs appears next to the primary destination DLCI number on the Management PVCs Options screen.

16 – 1007 – Specifies the DLCI number.

9128-A2-GB20-80

September 2002

4-69

Page 113
Image 113
Paradyne 9126-II, CSU, DSU manual PVC Connection Options 2, Source Edlci, Primary Destination Link, Primary Destination Dlci